FB2M5LRR 650 nm 10-250 MBd 50 m LC POF Transceiver w. RSSI
- Technology
- Optical transceivers
- Partner
- Firecomms
The FB2M5LRR is an LC fibre-optic transceiver for bidirectional serial communication over 2.2 mm plastic optical fibre. It combines a 650 nm RCLED transmitter, a PIN-diode CMOS receiver and an RSSI output in a compact through-hole housing. The device operates from 10 to 250 Mbps and supports a maximum NRZ symbol rate of 250 MBd. It can be used for 100Base-FX, EtherCAT, Sercos III, 200 Mbps 8B/10B links and proprietary FPGA or ASIC connections. AC-coupled interface circuits allow connection to LVDS, CML and LVPECL logic when the applicable common-mode and termination requirements are followed. A link length of up to 50 m is specified over step-index POF at 250 Mbps, although the achievable distance depends on the data rate and installation conditions. Automatic sleep functions and an analogue RSSI output support standby power management and optical link monitoring in industrial and robotic equipment.

Range features
A high level overview of what this range offers
- IEC 61754-20 LC housing with click-lock connection: Provides a compact, latching optical interface.
- 650 nm RCLED with integrated CMOS driver: Couples red optical output efficiently into 0.5 NA plastic optical fibre.
- 10–250 Mbps operating range: Supports industrial Ethernet and proprietary serial communication links.
- Up to 250 MBd NRZ symbol rate: Accommodates 200 Mbps payloads using 8B/10B encoding.
- LVDS, CML and LVPECL compatibility: Connects to common PHY, FPGA and ASIC differential interfaces through suitable AC-coupled networks.
- RSSI current output: Converts average received optical power into an analogue link-monitoring signal when used with a load resistor.
- Automatic transmitter and receiver sleep functions: Reduce combined typical sleep current to 27 µA when electrical and optical signals are absent.
- Receiver sensitivity down to -24 dBm: Provides a defined basis for calculating the optical link budget.
- -40 °C to +85 °C operating range: Supports installation in industrial temperature environments.
- Internally terminated receiver output: Provides 100 Ω differential termination between RD+ and RD−.
- Integrated shielding and differential signalling: Supports controlled PCB design for reduced crosstalk and external interference.
- LED Class 1, RoHS compliance and MSL 2a classification: Provides documented safety, material and handling parameters.
Downloads
for FB2M5LRR 650 nm 10-250 MBd 50 m LC POF Transceiver w. RSSI
What’s in this range?
All the variants in the range and a comparison of what they offer
General specifications
| Specification | Value |
|---|---|
Part number | FB2M5LRR |
Product type | Bidirectional LC fibre-optic transceiver with RSSI |
Connector and housing | LC, IEC 61754-20 compliant, black, click-lock connection |
Fibre interface | 2.2 mm POF cable; characterised with 1 mm core, 0.5 NA step-index POF |
Transmitter source | 650 nm RCLED with integrated CMOS driver |
Data rate | 10–250 Mbps; maximum NRZ symbol rate of 250 MBd |
Encoded link examples | 100 Mbps with 4B/5B at 125 MBd; 200 Mbps with 8B/10B at 250 MBd |
Specified link distance | 50 m over step-index POF at 250 Mbps, subject to data rate and installation conditions |
Supply voltage | 3.0–3.6 V; 3.3 V typical |
Electrical interfaces | LVDS, CML and LVPECL through suitable AC-coupled circuits |
Receiver termination | Internal 100 Ω differential termination between RD+ and RD− |
Transmitter termination | External 100 Ω differential termination required between TD+ and TD− |
Operating temperature | -40 °C to +85 °C |
Combined typical sleep current | 27 µA |
RSSI | Current proportional to average received optical power; 10 kΩ load-resistor example |
General dimensional tolerance | ±0.2 mm |
Typical applications | Industrial and robotic links, 100Base-FX, EtherCAT, Sercos III and proprietary serial links |
Transmitter electrical and optical characteristics
| Parameter | Symbol | Minimum | Typical | Maximum | Unit |
|---|---|---|---|---|---|
DC supply voltage | VCC | 3.0 | 3.3 | 3.6 | V |
Operating current consumption | ICC | — | 37 | 52 | mA |
Sleep-state current consumption | ISleep | — | 20 | 40 | µA |
Data rate | Baud rate | 10 | — | 250 | Mbps |
Data input capacitance | CIN | — | — | 5 | pF |
Single-ended data input resistance | RIN | — | 5 | — | kΩ |
Input common-mode range | VIN-BIAS | GND + 0.8 | — | VCC − 0.8 | V |
Input voltage swing | VIN-SWING | 100 | — | 1,200 | mV |
Differential voltage swing required for wake-up | Wake-up input | 50 | — | — | mV |
Wake-up time delay | TWU | — | 5 | 80 | µs |
Optical power-off delay | TOD | 0.02 | — | 20 | µs |
Peak wavelength | λpeak | 640 | 660 | 670 | nm |
Spectral bandwidth, FWHM | Δλ | — | 23 | 30 | nm |
Average optical power | P | -10 | — | -2.0 | dBm |
Optical rise time, 20% to 80% | tR | — | 2.0 | 2.8 | ns |
Optical fall time, 20% to 80% | tF | 0.3 | — | 0.6 | ns |
Optical modulation amplitude | OMA | 160 | 590 | 1,250 | µW |
Total jitter | JTOT | — | — | 1.6 | ns |
Receiver electrical and optical characteristics
| Parameter | Symbol | Minimum | Typical | Maximum | Unit |
|---|---|---|---|---|---|
DC supply voltage | VCC | 3.0 | 3.3 | 3.6 | V |
Data rate | BR | 10 | — | 250 | Mbps |
Operating current consumption | ICC | 18 | 22 | 30 | mA |
Sleep-state current consumption | IS | 2 | 7 | 15 | µA |
Output impedance between RD+ and RD− | ZDIFF | — | 100 | — | Ω |
Offset common-mode voltage | VOCM | 1.15 | 1.25 | 1.35 | V |
Output voltage peak-to-peak swing | VO-pp | 325 | 400 | 500 | mV |
Differential output voltage swing | Vdiff | 650 | 800 | 1,000 | mV |
Receivable optical power sensitivity | PIN | — | — | -24 | dBm |
Maximum allowed optical power | POL | — | — | -2 | dBm |
Rise time, 10% to 90% | tR | — | 0.4 | 1 | ns |
Fall time, 90% to 10% | tF | — | 0.4 | 1 | ns |
Optical power to enter sleep | PSL | -40 | -31 | — | dBm |
Optical power to wake from sleep | PWU | -28 | — | -26 | dBm |
Sleep-state delay | TSD | — | 2 | — | s |
Wake-up time from sleep | TWU-SLEEP | — | 100 | — | µs |
Receiver jitter with ideal input signal | JTOT | — | — | 1.5 | ns |
Voltage at RSSI | VRSSI | 0 | — | VCC − 1.5 | V |
RSSI output responsivity | IRSSI/PIN | — | 0.16 | — | A/W |
Transceiver pin description
| Pin | Section | Function | Symbol |
|---|---|---|---|
1 | Transmitter | EMI shield | GND |
2 | Transmitter | Negative signal input | TD− |
3 | Transmitter | Positive signal input | TD+ |
4 | Transmitter | Ground | GND |
5 | Transmitter | 3.3 V DC power input | VCC |
6 | Transmitter | Ground | GND |
7 | Receiver | 3.3 V DC power input | VCC |
8 | Receiver | Ground | GND |
9 | Receiver | Received signal strength indicator | RSSI |
10 | Receiver | Negative data output | RD− |
11 | Receiver | Positive data output | RD+ |
12 | Receiver | EMI shield | GND |
Regulatory compliance
| Parameter | Symbol | Standard | Level |
|---|---|---|---|
Storage compliance | MSL | J-STD-020 | 2a, four-week floor life |
Restriction of hazardous substances | RoHS | Directive 2011/65/EU | Compliant |
Eye safety | — | IEC 60825-1 | LED Class 1 |
Absolute maximum ratings
| Parameter | Symbol | Minimum | Maximum | Unit |
|---|---|---|---|---|
Storage temperature | Tstg | -40 | +85 | °C |
Operating temperature | Top | -40 | +85 | °C |
Soldering temperature | Tsld | — | +260 | °C |
Supply voltage | VR | -0.5 | 3.6 | V |
Packing information
| Packing parameter | Value |
|---|---|
Components per tube | 25 |
Tube length | 450 mm |
Tube width | 34.9 mm |
Tube height | 19.4 mm |
Tubes per bag | 10 |
Bags per inner carton | 1 |
Inner carton length | 588 mm |
Inner carton width | 147 mm |
Inner carton height | 82 mm |
Complete inner-carton weight | 1.95 kg |
Components per inner carton | 250 |
Inner cartons per outer carton | 4 |
Outer carton length | 600 mm |
Outer carton width | 310 mm |
Outer carton height | 195 mm |
Complete outer-carton weight | 8.10 kg |
Components per outer carton | 1,000 |
Characterisation and handling notes
Transmitter and receiver characterisation covers the full -40 °C to +85 °C operating range and a 3.0–3.6 V supply. Unless otherwise stated, maximum-rate measurements use a 250 Mbps PRBS7 pattern with optical power coupled through at least 0.5 m of 1 mm core, 0.5 NA step-index POF. The EMI shield pins should connect to the PCB signal-ground plane, and both transmitter ground pins must be connected because they are not internally linked.
The +260 °C soldering limit applies for 10 seconds, one time only, at least 2.2 mm from the lead root; absolute maximum ratings are damage limits rather than normal operating conditions. The transceiver is not suitable for infrared or vapour-phase reflow soldering, and the dust plug should remain fitted during soldering, washing and drying. Alcohol-based cleaning agents may be used, but acetone, ethyl acetate, phenol and similar solvents must not be applied. The unopened moisture-barrier bag has a stated shelf life of 24 months below 40 °C and 90% relative humidity. After opening, the permitted floor life is 672 hours below 30 °C and 60% relative humidity, or the components may be held in a dry cabinet below 10% relative humidity.
FAQs
for FB2M5LRR 650 nm 10-250 MBd 50 m LC POF Transceiver w. RSSI
The electrical and optical path supports data rates from 10 to 250 Mbps, while the serial symbol rate depends on the line encoding used. A 100 Mbps Ethernet stream using 4B/5B encoding operates at 125 MBd, whereas a 200 Mbps payload using 8B/10B encoding operates at 250 MBd. This makes 250 MBd the practical upper symbol-rate limit for the intended NRZ applications. When selecting a PHY or FPGA transceiver port, engineers should check the coded line rate rather than relying only on payload throughput. A design exceeding 250 MBd after encoding falls outside the characterised operating range.
Yes, a distance of 50 m over step-index POF is specified at 250 Mbps, but the final reach depends on the complete installation. The transmitter provides an average optical power range of -10 to -2 dBm, while the receiver sensitivity is -24 dBm and its maximum permitted optical input is -2 dBm. Comparing the minimum transmitted power with receiver sensitivity gives a nominal 14 dB optical budget before connector loss, fibre attenuation, bending, contamination, ageing and temperature effects are considered. The link budget should therefore be calculated using the actual cable and connector arrangement. Production hardware should also be tested across the required environmental range.
The data paths should normally be AC coupled so that each side can retain the common-mode voltage required by its own interface. The receiver has a typical common-mode output of 1.25 V, a typical 400 mV peak-to-peak output swing and an 800 mV differential swing. CML circuits generally operate with a 1.5 V common-mode level, while the illustrated LVPECL arrangement shifts the interface to 2 V through a resistor network. RD+ and RD− are internally terminated to 100 Ω, but TD+ and TD− require an external 100 Ω differential resistor. The 100 nF coupling capacitors used for high-speed operation may need to be increased at lower data rates.
The sleep functions reduce standby demand, but their timing must be considered when traffic starts after an idle period. The transmitter has a typical sleep current of 20 µA, the receiver typically draws 7 µA in sleep, and the combined typical value is therefore 27 µA. Transmitter wake-up delay is typically 5 µs and can reach 80 µs, while the receiver enters sleep after 2 seconds and requires 100 µs to wake. The receiver wake threshold lies between -28 and -26 dBm. Intermittent protocols may require a preamble, idle pattern or other valid signalling period before payload data is accepted.
The RSSI pin provides a current related to the average optical power reaching the receiver. Connecting a resistor between RSSI and ground converts this current into an analogue voltage, with 10 kΩ used in the example monitoring circuit. Typical RSSI responsivity is 0.16 A/W, and the available voltage range extends from 0 V to VCC minus 1.5 V. An ADC or comparator can use this signal to identify gradual link loss, contamination or excessive fibre bending before data reception fails. Thresholds should be calibrated in the finished assembly because RSSI is intended for link-health monitoring rather than precision optical-power measurement.
Pins 1 and 12 should connect the EMI shields directly to the signal-ground plane, and both transmitter ground pins must also be connected because they are not internally joined. A continuous, low-inductance ground plane helps limit transmitter-to-receiver crosstalk and external interference. TD+/TD− and RD+/RD− should be routed as controlled-impedance differential pairs with short, matched paths. Supply bypass capacitors should be placed close to the relevant power pins, and the recommended filtering should not be located remotely from the transceiver. The external 100 Ω transmitter termination should also be positioned to minimise stubs and discontinuities.
The component is intended for controlled soldering processes and is not suitable for infrared or vapour-phase reflow. Its maximum soldering condition is 260 °C for 10 seconds, applied once and at least 2.2 mm from the lead root. The MSL 2a classification permits a floor life of 672 hours below 30 °C and 60% relative humidity after the moisture-barrier bag is opened, while dry storage below 10% relative humidity is an alternative. The dust plug should remain installed during soldering, cleaning and drying. Alcohol-based cleaning agents are permitted, but acetone, ethyl acetate, phenol and similar solvents should be excluded from the process.