WDM Tap Iolator Hybrid 980/1550 nm & 1480/1550 nm Single / Dual Stage Isolator

The WTIH WDM tap coupler isolator hybrid combines wavelength routing, signal sampling and optical isolation within one passive component. It is designed for fibre-optic amplifiers, CATV links, WDM systems, optical instruments, transmitters and fibre lasers. Two wavelength combinations cover 980/1550 nm and 1480/1550 nm architectures, with pump ranges of 965 to 1000 nm or 1450 to 1490 nm. Single-stage versions cover a 1550 ±15 nm signal range, while dual-stage versions extend this to 1550 ±30 nm. Isolation is specified at a minimum of 31 dB for single-stage units and 45 dB for dual-stage units at 23°C across all states of polarisation. Tap ratios of 1%, 2% and 5% provide options for extracting a monitored signal while maintaining the main optical path. Fibre type, pigtail protection, fibre length and input and output connector selections allow the component to be configured around the assembly requirements.

WDM Tap Iolator Hybrid 980/1550 nm & 1480/1550 nm Single / Dual Stage Isolator

Range features

A high level overview of what this range offers

  • Integrated WDM, tap coupler and isolator: Can reduce the number of discrete passive components required in an optical assembly.
  • 980/1550 nm and 1480/1550 nm variants: Supports two pump and signal wavelength architectures.
  • Single- and dual-stage options: Allows selection between at least 31 dB and 45 dB isolation.
  • 1%, 2% and 5% tap ratios: Provides a choice of signal sampling levels and defined tap-path losses.
  • Specified signal insertion-loss limits: Limits range from ≤0.9 dB to ≤1.4 dB according to wavelength, stage and tap ratio.
  • Low polarisation sensitivity: Polarisation-dependent loss is limited to ≤0.1 dB, with PMD dependent on the stage and selected option.
  • Epoxy-free optical path: Keeps adhesive outside the active optical transmission path.
  • High directivity and return loss: Provides ≥55 dB directivity and ≥50 dB return loss before connector effects.
  • Compact cylindrical package: Uses a 5.5 mm diameter housing with a length of 38 mm or 42 mm, depending on the fibre construction.
  • Configurable fibre interfaces: Offers bare fibre or 900 µm loose tube with several fibre, length and connector choices.

Downloads

for WDM Tap Iolator Hybrid 980/1550 nm & 1480/1550 nm Single / Dual Stage Isolator

pdf
WTIH 980/1550 nm and 1480/1550 nm WDM Tap Coupler Isolator Hybrid Datasheet
Download

What’s in this range?

All the variants in the range and a comparison of what they offer

Specifications

ParameterSpecification

Operating wavelength combinations

980/1550 nm; 1480/1550 nm

Stage options

Single; dual

Tap ratio options

1%; 2%; 5%

Port configuration

2×2

Pump insertion loss

≤0.6 dB

Tap-path insertion loss, 1% tap

19 to 20.8 dB

Tap-path insertion loss, 2% tap

16.2 to 18.0 dB

Tap-path insertion loss, 5% tap

12.2 to 14.0 dB

Wavelength-dependent loss

≤0.4 dB

Polarisation-dependent loss

≤0.1 dB

Directivity

≥55 dB

Return loss

≥50 dB

Maximum optical power

300 mW

Operating temperature

0 to +70°C

Storage temperature

-40 to +85°C

Signal and tap-port fibre

SMF-28, SMF-28 Ultra or ClearCurve ZBL

Package

A package; Ø5.5 × 38 mm with 250 µm fibre; Ø5.5 × 42 mm with 900 µm fibre

Variant comparison

Parameter980/1550 nm Single980/1550 nm Dual1480/1550 nm Single1480/1550 nm Dual

Signal wavelength

1550 ±15 nm

1550 ±30 nm

1550 ±15 nm

1550 ±30 nm

Pump wavelength

965 to 1000 nm

965 to 1000 nm

1450 to 1490 nm

1450 to 1490 nm

Isolation at 23°C, all SOP

≥31 dB

≥45 dB

≥31 dB

≥45 dB

Signal-path wavelength isolation, ports 2→4

≥12 dB

≥12 dB

≥12 dB

≥12 dB

Pump-path wavelength isolation, ports 1→2 or 2→1

≥30 dB

≥30 dB

≥30 dB

≥30 dB

Signal insertion loss, 1% or 2% tap

≤1.1 dB

≤1.2 dB

≤0.9 dB

≤1.1 dB

Signal insertion loss, 5% tap

≤1.3 dB

≤1.4 dB

≤1.1 dB

≤1.3 dB

Polarisation mode dispersion

≤0.25 dB; ≤0.05 dB option

≤0.05 dB

≤0.25 dB; ≤0.05 dB option

≤0.05 dB

Pump and common-port fibre

Hi1060 or Hi1060 Flex

Hi1060 or Hi1060 Flex

SMF-28, SMF-28 Ultra or ClearCurve ZBL

SMF-28, SMF-28 Ultra or ClearCurve ZBL

Insertion-loss limits apply across the overall wavelength range from 0 to +70°C and all states of polarisation. Optical values exclude connector effects. PMD values retain the stated dB unit because no alternative unit is provided.

Ordering information

Order-code segmentCode optionsSelection

Product prefix

WTIH

WDM/tap coupler/isolator hybrid

Stage

S; D

S = Single; D = Dual

Operating wavelength

9855; 4855

9855 = 980/1550 nm; 4855 = 1480/1550 nm

Tap ratio

1; 2; 5

1 = 1%; 2 = 2%; 5 = 5%

Port

202

2×2 configuration

Package

A

A package

Pump and common-port fibre

2; 3; 6; 7

2 = SMF-28 Ultra, G.657.A1; 3 = ClearCurve ZBL, G.657.B3; 6 = Hi1060; 7 = Hi1060 Flex

Signal and tap-port fibre

2; 3

2 = SMF-28 Ultra, G.657.A1; 3 = ClearCurve ZBL, G.657.B3

Pigtail style

1; 2

1 = Bare fibre; 2 = 900 µm loose tube

Fibre length

05; 10; 20

05 = 0.5 m; 10 = 1.0 m; 20 = 2.0 m

Input connector

0 to 7

0 = None; 1 = FC/APC; 2 = FC/PC; 3 = SC/APC; 4 = SC/PC; 5 = ST; 6 = LC/UPC; 7 = LC/APC

Output connector

0 to 7

0 = None; 1 = FC/APC; 2 = FC/PC; 3 = SC/APC; 4 = SC/PC; 5 = ST; 6 = LC/UPC; 7 = LC/APC

Assemble the order code in this sequence: WTIH → Stage → Operating wavelength → Tap ratio → Port → Package → Pump/common fibre → Signal/tap fibre → Pigtail style → Fibre length → Input connector → Output connector.

SMF-28 compliant with G.652 is available on request for applicable fibre positions. Other fibre lengths are also available on request, but the 900 µm loose-tube option is limited to 2 m.

FAQs

for WDM Tap Iolator Hybrid 980/1550 nm & 1480/1550 nm Single / Dual Stage Isolator

Select the 980/1550 nm version when the pump wavelength is within 965 to 1000 nm, and the 1480/1550 nm version when it is within 1450 to 1490 nm. In both cases, the single-stage version covers a 1550 ±15 nm signal band and provides at least 31 dB isolation at 23°C across all states of polarisation. The dual-stage version widens the signal band to 1550 ±30 nm and raises isolation to at least 45 dB. The final selection should balance pump wavelength, required signal bandwidth, isolation and the insertion-loss limit of the chosen configuration.

Choose the tap ratio by balancing the power required at the monitoring port against the permitted loss in the main signal path. Tap-path insertion loss is 19 to 20.8 dB for 1%, 16.2 to 18.0 dB for 2% and 12.2 to 14.0 dB for 5%, so the 5% version provides the strongest sampled output. The 5% option also increases the permitted main-signal insertion loss by 0.2 dB compared with the 1% and 2% versions across every wavelength and stage combination. In practice, the monitor receiver sensitivity and end-to-end optical power budget should determine the tap selection.

Select the pump and common-port fibre according to the wavelength combination. The 980/1550 nm versions use Hi1060 or Hi1060 Flex, while the 1480/1550 nm versions support SMF-28, SMF-28 Ultra or ClearCurve ZBL. The signal and tap ports support SMF-28, SMF-28 Ultra or ClearCurve ZBL for both wavelength variants. Ordering options identify SMF-28 Ultra as G.657.A1 and ClearCurve ZBL as G.657.B3, with SMF-28 compliant with G.652 available on request. No mode-field-diameter or splice-loss figures are defined, so these interface characteristics should be confirmed at assembly level.

Launched optical power must remain at or below 300 mW, with operation limited to 0 to +70°C and storage permitted from -40 to +85°C. The insertion-loss limits are defined over the operating wavelength range from 0 to +70°C and across all states of polarisation. No power derating curve or connector-inclusive optical power rating is defined. A design operating near the temperature or power ceiling should therefore include system-level margin and validate the completed optical assembly under its intended thermal and launch-power conditions.

Choose the pigtail construction before finalising the mechanical layout because it changes the package length. The standard A package is Ø5.5 × 38 mm with 250 µm fibre and Ø5.5 × 42 mm with 900 µm fibre. Pigtails can be supplied as bare fibre or 900 µm loose tube, with standard length codes for 0.5 m, 1.0 m and 2.0 m. Other lengths can be requested, although the 900 µm loose-tube construction is limited to 2 m. Bare fibre can support compact splice management, while loose tubing can provide additional handling protection where the installation permits the longer package.

The component has separate specifications for isolator performance, wavelength rejection and reflection control. Optical isolation is at least 31 dB for single-stage versions and 45 dB for dual-stage versions at 23°C across all states of polarisation. Wavelength isolation is at least 12 dB on the signal path from ports 2 to 4 and at least 30 dB on the pump path between ports 1 and 2. Directivity is at least 55 dB and return loss is at least 50 dB. These values help determine how the component manages unwanted propagation and reflections, but connector effects must be added separately when evaluating the assembled system.

No, the optical performance figures exclude connectors. Input and output connector positions can each be configured as none, FC/APC, FC/PC, SC/APC, SC/PC, ST, LC/UPC or LC/APC. A connectorised assembly therefore requires the connector-dependent insertion loss and return loss to be included separately in the system budget. The polish and interface type should also match the adjoining equipment to avoid an unintended optical junction. For fusion-spliced installations, selecting no connector and specifying the required pigtail style and length can simplify the interface arrangement.