Optical Switch 1×8 Mechanical Latching Single / Dual Operatng Wavelength Windows
- Technology
- Passive optical components
- Partner
- AC Photonics
The MS 1×8 mechanical single-mode fibre-optic switch routes one common optical path to one of eight selectable outputs using electrically controlled opto-mechanical switching. Its bidirectional signal path supports single-window operation from 1260–1360 nm or 1510–1560 nm and dual-window operation at 1310/1550 nm with ±30 nm windows. The latching configuration is selected through the order code, while non-latching operation is also listed for the wider series. A 3.3 V CMOS interface provides three address inputs together with Strobe, Busy and Error signals. Applications include optical network protection and restoration, configurable optical add/drop routing, transmitter and receiver protection, instrumentation and network test systems. Fibre standard, pigtail construction, length and input and output connectors can be configured for the installation. Integration requires both 5 V and 3.3 V supplies and allowance for the specified 86 × 80 × 20 package size. The optical path is epoxy-free, and the construction is RoHS compliant.

Range features
A high level overview of what this range offers
- Mechanical 1×8 optical routing: Directs the common single-mode path to one of eight selectable outputs.
- Bidirectional operation: Allows optical signals to travel through the selected path in either direction.
- Single or dual operating windows: Supports 1260–1360 nm, 1510–1560 nm or dual 1310/1550 nm operation with ±30 nm windows.
- Latching configuration: Provides a defined latching option through the product order code.
- Controlled insertion loss: Limits insertion loss to ≤1.5 dB for single-window versions and ≤1.8 dB for dual-window versions.
- High optical isolation: Delivers channel crosstalk of ≥50 dB and return loss of ≥55 dB.
- Stable route selection: Provides repeatability of ±0.05 dB over repeated switching operations.
- Long operating life: Supports up to 10 million switching cycles.
- Fast switching: Completes switching within a maximum of 25 ms.
- 3.3 V CMOS interface: Uses D0–D2 address lines with Strobe, Busy and Error signals for controller integration.
- Configurable optical connections: Offers selectable fibre standards, pigtail styles, lengths and independent input and output terminations.
- Epoxy-free optical path: Keeps epoxy outside the optical signal path.
- RoHS-compliant construction: Supports equipment subject to RoHS material requirements.
Downloads
for Optical Switch 1x8 Mechanical Latching Single / Dual Operatng Wavelength Windows
What’s in this range?
All the variants in the range and a comparison of what they offer
Core specifications
| Parameter | Specification |
|---|---|
Product configuration | One common optical path to one of eight selectable output ports |
Switching technology | Opto-mechanical |
Optical directionality | Bidirectional |
Operating mode | Latching option; non-latching operation is also listed for the wider series |
Operating windows | Single or dual |
Grade | P |
Polarisation-dependent loss | ≤0.20 dB |
Channel crosstalk | ≥50 dB |
Return loss | ≥55 dB |
Repeatability | ±0.05 dB |
Maximum switching time | ≤25 ms |
Power supplies | +5 V DC and +3.3 V DC |
+5 V supply current | ≤200 mA |
Digital interface logic | CMOS, 3.3 V |
Additional timing value | ≤10 ms; the associated parameter is not identified clearly |
Durability | 10 million cycles |
Optical power | ≤300 mW |
Operating temperature | 0 to +70 °C |
Storage temperature | −40 to +85 °C |
Package dimensions, L × W × H | 86 × 80 × 20; unit not explicitly stated |
Electrical pin assignment | Pin 1: +5 V; pin 2: GND; pin 3: D0; pin 4: D1; pin 5: D2; pin 6: Strobe; pin 7: Busy; pin 8: Error; pin 9: GND; pin 10: +3.3 V |
Compliance | RoHS compliant |
Optical specification reference condition | Values exclude connectors |
Single- and dual-window comparison
| Specification | Single window | Dual window |
|---|---|---|
Operating wavelength | 1260–1360 nm or 1510–1560 nm | 1310/1550 nm ±30 nm |
Grade | P | P |
Insertion loss | ≤1.5 dB | ≤1.8 dB |
Wavelength-dependent loss | ≤0.25 dB | ≤0.30 dB |
Port-selection logic
| Data input | Port 1 | Port 2 | Port 3 | Port 4 | Port 5 | Port 6 | Port 7 | Port 8 |
|---|---|---|---|---|---|---|---|---|
D0 | 0 | 1 | 0 | 1 | 0 | 1 | 0 | 1 |
D1 | 0 | 0 | 1 | 1 | 0 | 0 | 1 | 1 |
D2 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 |
Ordering scheme
| Segment | Code | Selection |
|---|---|---|
Series | MS | Series prefix |
Option | L | Latching |
Grade | P | P grade |
Operating wavelength | 31 | 1260–1360 nm |
Operating wavelength | 55 | 1510–1610 nm |
Operating wavelength | 3155 | 1310/1550 nm |
Port | 108 | 1×8 |
Fibre type | 1 | G.652 single-mode fibre, available on request |
Fibre type | 2 | G.657.A1 single-mode fibre |
Fibre type | 3 | G.657.B3 single-mode fibre |
Pigtail style | 1 | Bare fibre |
Pigtail style | 2 | 900 µm loose tube |
Fibre length | 05 | 0.5 m |
Fibre length | 10 | 1.0 m |
Fibre length | 20 | 2.0 m |
Input connector | 0 | None |
Input connector | 1 | FC/APC |
Input connector | 2 | FC/PC |
Input connector | 3 | SC/APC |
Input connector | 4 | SC/PC |
Input connector | 5 | ST |
Input connector | 6 | LC/UPC |
Input connector | 7 | LC/APC |
Output connector | 0 | None |
Output connector | 1 | FC/APC |
Output connector | 2 | FC/PC |
Output connector | 3 | SC/APC |
Output connector | 4 | SC/PC |
Output connector | 5 | ST |
Output connector | 6 | LC/UPC |
Output connector | 7 | LC/APC |
Segment sequence: MS + Option + Grade + Operating wavelength + Port + Fibre type + Pigtail style + Fibre length + Input connector + Output connector.
Ordering note: The specified performance range for the upper single window is 1510–1560 nm, while ordering code 55 is defined as 1510–1610 nm. Confirm the required upper wavelength limit before ordering.
FAQs
for Optical Switch 1×8 Mechanical Latching Single / Dual Operatng Wavelength Windows
The dual-window version is appropriate when the same switch must handle both nominal 1310 nm and 1550 nm signals, as it covers 1310/1550 nm with a ±30 nm window around each band. For a design confined to one band, the single-window choices are 1260–1360 nm or 1510–1560 nm, with a lower specified insertion loss of ≤1.5 dB compared with ≤1.8 dB for the dual-window version. Wavelength-dependent loss is also tighter at ≤0.25 dB for single-window operation versus ≤0.30 dB for dual-window operation. The ordering code labels the upper single window as 1510–1610 nm, which does not match the 1510–1560 nm performance range. Confirm the required upper wavelength limit before ordering, especially for systems operating above 1560 nm.
The interface requires a 5 V rail for switch power and a 3.3 V rail for CMOS control logic. The 5 V supply current is specified at ≤200 mA, while the ten-pin interface assigns +5 V to pin 1, grounds to pins 2 and 9, D0–D2 to pins 3–5, Strobe to pin 6, Busy to pin 7, Error to pin 8 and +3.3 V to pin 10. The controller should set D0–D2, issue the strobe command and use Busy and Error for sequencing and fault handling. Keep the 3.3 V logic levels isolated from the 5 V supply domain in the controller design. A separate ≤10 ms timing value is present but is not tied unambiguously to a named parameter, so it should not be used as a design limit without confirmation.
Ports are selected with a three-bit binary address on D2, D1 and D0. Port 1 uses 000, port 2 uses 001, port 3 uses 010, and the sequence continues to port 8 at 111, with D0 acting as the least significant bit. This mapping allows a microcontroller, FPGA or digital I/O device to address all eight outputs with three data lines. The Strobe input initiates the change, while Busy and Error provide feedback for transaction control. Because detailed setup, hold and strobe timing is not defined, firmware should avoid changing the address lines during a switching operation, and the final timing sequence should be confirmed during integration.
Allow up to 1.5 dB insertion loss for single-window units or 1.8 dB for dual-window units before adding connector-related losses. The stated optical values exclude connectors, so the loss budget must separately include both input and output connector pairs, splices and fibre routing. Channel crosstalk is ≥50 dB, return loss is ≥55 dB, polarisation-dependent loss is ≤0.20 dB and repeatability is ±0.05 dB. Wavelength-dependent loss is ≤0.25 dB for single-window operation and ≤0.30 dB for dual-window operation, which matters when broadband sources or multiple wavelengths share the path. Use the worst-case figures for the selected wavelength and add the installation and ageing margin required by the system design.
The switch can be used for network protection and restoration, configurable optical add/drop routing, transmitter and receiver protection, instrumentation and automated network testing. The maximum switching time is ≤25 ms, so protection logic must account for that device-level limit as well as controller detection, decision and communication delays. Bidirectional optical operation allows the same path architecture to be used regardless of signal direction, while the order code provides a latching configuration for designs requiring that actuation type. Durability is rated at 10 million cycles and repeatability at ±0.05 dB, both of which are relevant to frequently exercised test systems. No protocol-specific failover class or system availability figure is defined, so those requirements must be validated at equipment level.
The order code supports G.657.A1 or G.657.B3 single-mode fibre, with G.652 fibre available on request. Pigtails can be specified as bare fibre or 900 µm loose tube, and the listed lengths include 0.5 m, 1.0 m and 2.0 m. Input and output terminations can independently be left unterminated or fitted with FC/APC, FC/PC, SC/APC, SC/PC, ST, LC/UPC or LC/APC connectors. Fibre choice should reflect bend-radius constraints and the cabling already used in the enclosure, while connector polish should match the mating interface and return-loss requirement. Since connector loss is excluded from the optical performance values, the selected terminations must be included separately in the end-to-end budget.
The package is listed as 86 × 80 × 20, although the unit is not explicitly identified in the specification row, so it should be confirmed before the enclosure is finalised. Additional clearance is required for fibre exit, pigtail routing and connector strain relief. The operating range is 0 to +70 °C and the storage range is −40 to +85 °C, meaning that the enclosure must maintain the active temperature even if the wider equipment has a broader storage rating. Optical power is specified at ≤300 mW and should be treated as the stated upper value unless a lower application-specific limit applies. The mechanical drawing should be used for mounting-hole positions and tolerances rather than estimating dimensions from the illustration.
The ordering scheme identifies L as the latching option, while the wider series description also mentions non-latching operation. The electrical interface still uses D0–D2, Strobe, Busy and Error, but separate details are not provided for state retention after power removal, startup position, reset behaviour or the control pulse associated with latching. Those behaviours affect protection systems because an unexpected default route can alter the optical path during power cycling. Confirm the required power-off state, command timing and recovery sequence before finalising the controller. This is also important when replacing a non-latching switch, as identical optical specifications do not guarantee identical control behaviour.