PM Optical Isolator Short Wavelength Single Stage 600 mW PM850 / PM980

The PMIS short-wavelength PM optical isolator is a single-stage device for controlling reverse-propagating light in polarisation-maintaining fibre assemblies. It is offered at five discrete wavelengths: 830, 850, 980, 1030 and 1060 nm, each with a ±10 nm bandwidth. PM850 fibre is used for the 830 and 850 nm versions, while PM980 fibre is used for the 980, 1030 and 1060 nm versions. Grade P optical performance comprises 25 dB typical peak isolation, at least 20 dB minimum isolation, 0.80 dB typical insertion loss and a 1.20 dB insertion-loss limit before connector effects. Typical applications include fibre-optic amplifiers, pump laser sources, fibre-optic sensors, test and measurement equipment, and instrumentation. The A package measures 52 × 28 × 27 mm and supports slow-axis, fast-axis or both-axis working configurations. Configurable pigtails and independent input and output connector options allow the assembly to be matched to the surrounding optical system. Connectorised designs should account for the specified changes to insertion loss, return loss and extinction ratio.

PM Optical Isolator Short Wavelength Single Stage 600 mW PM850 / PM980

Range features

A high level overview of what this range offers

  • Five discrete wavelength options with ±10 nm bandwidth – Supports 830, 850, 980, 1030 and 1060 nm optical architectures.
  • PM850 and PM980 fibre configurations – Matches the PM fibre type to the selected operating wavelength.
  • 25 dB typical peak isolation and ≥20 dB minimum isolation – Helps control reverse-propagating optical power.
  • 0.80 dB typical and ≤1.20 dB insertion loss – Provides defined forward-path loss figures for optical budgeting.
  • ≥50 dB return loss – Supports reflection-sensitive PM fibre assemblies.
  • ≥25 dB typical extinction ratio – Helps retain polarisation alignment within the specified fibre-length conditions.
  • ≤0.20 ps polarisation-mode dispersion – Limits the isolator’s differential delay contribution.
  • Optical power rating up to 600 mW – Defines the maximum continuous optical loading for system design.
  • Multiple connectors, pigtails and working-axis options – Allows the configuration to be adapted to the optical interface.
  • 52 × 28 × 27 mm A package – Provides a defined envelope for mechanical integration.

Downloads

for PM Optical Isolator Short Wavelength Single Stage 600 mW PM850 / PM980

pdf
Short-Wavelength PM Isolator 830/850/980/1030/1060 nm Datasheet
Download

What’s in this range?

All the variants in the range and a comparison of what they offer

Specifications

ParameterSpecification

Product type

Single-stage short-wavelength PM optical isolator

Operating wavelength options

830 nm, 850 nm, 980 nm, 1030 nm or 1060 nm

Grade

P

Typical peak isolation

25 dB

Minimum isolation

≥20 dB

Typical insertion loss

0.80 dB

Maximum insertion loss

≤1.20 dB

Return loss

≥50 dB

Extinction ratio

≥25 dB typical; ≥20 dB minimum

Polarisation-mode dispersion

≤0.20 ps

Bandwidth

±10 nm

Fibre type

PM850 for 830/850 nm; PM980 for 980/1030/1060 nm

Maximum optical power

≤600 mW

Operating temperature

0 to +60 °C

Storage temperature

−40 to +85 °C

Package

A package

Package dimensions

52 × 28 × 27 mm

Specification notes

  • Optical performance values are referenced without connectors.
  • Connectorised devices have 0.3 dB higher insertion loss, 5 dB lower return loss and 2 dB lower extinction ratio.
  • The extinction-ratio ratings apply to fibre lengths of 0.75 m or less. Increasing the fibre length can reduce the extinction ratio.
  • The PM fibre and connector key are aligned to the slow axis.

The configuration is assembled from left to right using the ordering fields shown above. Other fibre lengths can be requested, but the 900 µm loose-tube pigtail is limited to a maximum length of 2 m.

FAQs

for PM Optical Isolator Short Wavelength Single Stage 600 mW PM850 / PM980

The fibre type should be selected by nominal wavelength rather than used interchangeably. PM850 is specified for the 830 and 850 nm versions, while PM980 is specified for the 980, 1030 and 1060 nm versions. Each wavelength option has a ±10 nm bandwidth, so the source centre wavelength, manufacturing tolerance and expected thermal or drive-current drift should remain inside that window. The product is ordered as one discrete wavelength variant; it is not a continuously broadband isolator spanning 830 to 1060 nm. For design release, match both the wavelength code and fibre code to the laser or amplifier architecture.

Use ≥20 dB as the minimum isolation and 25 dB only as the typical peak value. The unconnectorised typical insertion loss is 0.80 dB, with a stated limit of ≤1.20 dB, so both nominal and worst-case figures should be included in link-budget calculations. For connectorised devices, the assembly adjustment is +0.3 dB insertion loss, producing 1.10 dB typical and 1.50 dB against the maximum when the offset is applied. This adjustment is defined for a device with connectors rather than as a per-connector value. In practice, design around the minimum isolation and maximum adjusted insertion loss rather than the typical figures.

Connectorised versions are suitable where a removable interface is required, while bare-fibre versions avoid the defined connector penalties. Input and output can each be configured as none, FC/APC, FC/PC, SC/APC, SC/PC, ST, LC/UPC or LC/APC. Adding connectors raises insertion loss by 0.3 dB, lowers return loss by 5 dB and lowers extinction ratio by 2 dB relative to the unconnectorised ratings. Applying these adjustments gives ≥45 dB return loss, ≥23 dB typical extinction ratio and ≥18 dB minimum extinction ratio for a connectorised assembly. Select the connector style for the surrounding interface, then use the adjusted figures in the optical budget.

The extinction-ratio figures apply when the fibre length is 0.75 m or shorter. Standard ordering codes cover 0.75 m and 1.0 m pigtails, but increasing fibre length can reduce extinction ratio, so the 1.0 m option should not automatically be budgeted at the short-fibre values. Other lengths can be requested, and a 900 µm loose-tube pigtail is limited to a maximum of 2 m. Where polarisation purity is critical, specify the shortest practical pigtail and confirm the expected extinction ratio for any length above 0.75 m. This is particularly relevant when extra service loops are being considered inside the enclosure.

The isolator can be ordered for slow-axis working, fast-axis working or operation on both axes. The PM fibre and connector key are aligned to the slow axis, giving the mechanical connector orientation a defined polarisation reference even when a different working-axis option is selected. The launch polarisation, mating adaptor orientation and downstream PM components therefore need to follow the chosen axis configuration. A mismatch can consume the available extinction-ratio margin even when the wavelength and connector type are correct. Record the S, F or B working-axis code in the build specification and verify the complete polarisation path during integration.

The device is rated for operation from 0 to +60 °C and storage from −40 to +85 °C. Its A package envelope is 52 × 28 × 27 mm, which should be used for initial mechanical allocation. These temperature ratings define the allowed device environment but do not specify thermal resistance, heat-sinking performance or power derating. The enclosure should keep the local isolator temperature within the operating range under the worst ambient and internal conditions. Additional space should be reserved for pigtail routing, strain relief and connector access, as these are not included in the package envelope.

The optical input should not exceed 600 mW, and the specified polarisation-mode dispersion is ≤0.20 ps. These limits address different design concerns: the power rating sets the optical loading ceiling, while PMD indicates the differential delay contribution that can matter in short-pulse or timing-sensitive systems. No separate peak-power, pulse-energy or pulse-width rating is defined, so 600 mW should not automatically be treated as an allowable pulsed peak power. For continuous-wave systems, keep the maximum operating condition within the 600 mW limit, including source tolerance. Pulsed-laser applications require an application-specific power assessment before the design is finalised.