PM Mini-Optical Switch 1×4 Solid-State 2 µs Ultra-Fast Unidirectional / Bidirectional

The MSS ultra-fast solid-state PM mini 1×4 fibre-optic switch provides electrically controlled routing for polarisation-maintaining optical signals. It directs an incoming signal to one of four selectable output fibres using a solid-state, non-mechanical switching arrangement. Latching operation and repeatability of ±0.01 dB support applications that require consistent path selection over repeated switching cycles. Two speed classes are available: a regular 50–200 µs variant and an ultra-fast 2–20 µs variant with a typical switching time of 5 µs. Engineers can select unidirectional routing or a bidirectional configuration that allows the chosen optical path to operate in both directions. Typical applications include optical network protection, configurable optical add/drop systems, transmitter and receiver protection, automated test equipment and optical instrumentation. The switch supports 1525–1565 nm operation or a customer-specified wavelength, optical power up to 500 mW and operating temperatures from –5 to +70 °C.

PM Mini-Optical Switch 1x4 Solid-State 2 µs Ultra-Fast Unidirectional / Bidirectional

Range features

A high level overview of what this range offers

  • 1 × 4 PM signal routing: Selects one of four optical output paths from a single input.
  • Solid-state, non-mechanical architecture: Supports high-cycle switching without a moving switching mechanism.
  • Ultra-fast switching option: Provides 2–20 µs switching with a typical value of 5 µs.
  • Regular switching option: Offers 50–200 µs operation where the ultra-fast electrical drive is not required.
  • Unidirectional and bidirectional configurations: Allows the optical direction to be matched to the system topology.
  • PER of at least 18 dB: Supports polarisation-maintaining optical paths.
  • Repeatability of ±0.01 dB: Helps maintain consistent loss when returning to a selected channel.
  • Latching operation: Supports electrically commanded path selection using the applicable voltage or pulse drive.
  • Optical power up to 500 mW: Defines the maximum optical input for system power budgeting.
  • Configurable terminations: Provides FC, SC, ST and LC connector options, bare fibre or 900 µm loose tube.
  • –5 to +70 °C operation: Supports use across the stated equipment temperature range.
  • RoHS-compliant designation: Supports component selection where RoHS status is required.

Downloads

for PM Mini-Optical Switch 1x4 Solid-State 2 µs Ultra-Fast Unidirectional / Bidirectional

pdf
MSS Mini 1×4 Solid-State PM Fibre-Optic Switch Datasheet
Download

What’s in this range?

All the variants in the range and a comparison of what they offer

Performance specifications

ParameterUnidirectionalBidirectional

Port configuration

1 × 4 unidirectional

1 × 4 bidirectional

Operating wavelength

1525–1565 nm or customer-specified wavelength

1525–1565 nm or customer-specified wavelength

Insertion loss

≤ 1.5 dB

≤ 1.8 dB

Wavelength-dependent loss

≤ 0.30 dB

≤ 0.30 dB

Temperature-dependent loss

≤ 0.30 dB

≤ 0.30 dB

Channel crosstalk

≥ 30 dB

≥ 30 dB

Return loss

≥ 40 dB

≥ 30 dB

Polarisation extinction ratio

≥ 18 dB

≥ 18 dB

Repeatability

±0.01 dB

±0.01 dB

Regular switching speed

50–200 µs

50–200 µs

Ultra-fast switching speed

2–20 µs

2–20 µs

Regular variant durability

≥ 100 billion cycles

≥ 100 billion cycles

Ultra-fast variant durability

≥ 1,000 billion cycles

≥ 1,000 billion cycles

Optical power

≤ 500 mW

≤ 500 mW

Operating temperature

–5 to +70 °C

–5 to +70 °C

Storage temperature

–40 to +85 °C

–40 to +85 °C

All optical values are referenced without connectors. The stated package dimensions are 37 × 16 × 7.5, but the source does not identify the unit.

Electrical specifications and speed comparison

ParameterUnitRegularUltra-fast

Switching speed

µs

50–200

2–20, typical 5

Switching voltage, Vcc

V

3 ±5%

3–7.5

Switching current

mA

≤ 100

≤ 350

Driving mode

—

Voltage or pulse driving

Pulse driving

Typical pulse width

µs

≤ 500, typical 300

≤ 200

Claim frequency

Hz

≤ 1,000

≤ 3,500

Other switching speeds are available by request.

Optical path and electrical pin configuration

ConfigurationOptical pathPin 1Pin 2Pin 3Pin 4

Unidirectional

IN → OUT 1

+

−

+

−

Unidirectional

IN → OUT 2

−

+

−

+

Unidirectional

IN → OUT 3

+

−

−

+

Unidirectional

IN → OUT 4

−

+

+

−

Bidirectional

IN ↔ OUT 1

+

−

+

−

Bidirectional

IN ↔ OUT 2

−

+

−

+

Bidirectional

IN ↔ OUT 3

+

−

−

+

Bidirectional

IN ↔ OUT 4

−

+

+

−

Segment sequence: MSS | Configuration | Switching speed | Operating wavelength | Port | Package | Fibre type | Pigtail style | Fibre length | Input connector | Output connector | Working axis

Ordering information

SegmentCodes and available options

Series prefix

MSS

Configuration

U = unidirectional; B = bidirectional

Switching speed

1 = 50–200 µs; 2 = 2–20 µs

Operating wavelength

55 = 1525–1565 nm; SS = specify

Port

104 = 1 × 4

Package

A = A package

Fibre type

M = PM1310; N = PM1550

Pigtail style

1 = bare fibre; 2 = 900 µm loose tube

Fibre length

07 = 0.75 m; 10 = 1.0 m; other lengths by request

Input connector

0 = none; 1 = FC/APC; 2 = FC/PC; 3 = SC/APC; 4 = SC/PC; 5 = ST; 6 = LC/UPC; 7 = LC/APC

Output connector

0 = none; 1 = FC/APC; 2 = FC/PC; 3 = SC/APC; 4 = SC/PC; 5 = ST; 6 = LC/UPC; 7 = LC/APC

Working axis

S = slow axis; B = both axes; F = fast axis

Other fibre lengths are available by request. The 900 µm loose-tube option is limited to a maximum length of 2 m.

FAQs

for PM Mini-Optical Switch 1×4 Solid-State 2 µs Ultra-Fast Unidirectional / Bidirectional

Choose the unidirectional version when light travels only from the input to the selected output, and the bidirectional version when the same optical path must operate in either direction. Both variants provide 1 × 4 routing, channel crosstalk of at least 30 dB, PER of at least 18 dB and repeatability of ±0.01 dB. The unidirectional configuration has the tighter insertion-loss limit at ≤1.5 dB, compared with ≤1.8 dB bidirectionally, and its return-loss rating is ≥40 dB rather than ≥30 dB. In practice, unidirectional routing suits fixed-direction links with tighter optical budgets, while bidirectional routing is appropriate where reciprocal path use is required. Connector effects must be added separately because the optical ratings exclude connectors.

Select the ultra-fast variant when the system requires a switching time between 2 and 20 µs, with a typical value of 5 µs. The regular variant switches in 50–200 µs and has a stated claim-frequency limit of 1,000 Hz, while the ultra-fast version is rated up to 3,500 Hz. Ultra-fast durability is at least 1,000 billion cycles, compared with at least 100 billion cycles for the regular version. This speed requires a pulse driver capable of supplying up to 350 mA at 3–7.5 V, whereas the regular type requires up to 100 mA at 3 V ±5%. The faster option therefore suits rapid protection, test and routing sequences, provided the control electronics can meet its higher drive requirements.

Select the wavelength code, PM fibre type and working axis as a coherent set that matches the surrounding optical system. The standard wavelength option covers 1525–1565 nm, while the SS ordering code is used when another operating wavelength is required. Fibre options are PM1310 and PM1550, and the working-axis field allows the slow axis, fast axis or both axes to be selected. The switch has a polarisation extinction ratio of at least 18 dB, so connector keying, fibre orientation and splice alignment remain important to the realised system performance. Where the standard wavelength band does not match the required fibre arrangement, specify the wavelength rather than assuming that every ordering combination is interchangeable.

Begin with the maximum insertion loss of 1.5 dB for the unidirectional version or 1.8 dB for the bidirectional version. These limits exclude connectors, so the losses of the selected input connector, output connector, splices and adjoining fibre must be added separately. Wavelength-dependent loss and temperature-dependent loss are each limited to 0.30 dB, which should be considered when calculating performance across the wavelength band and operating temperature range. Return loss, crosstalk and PER should be treated as separate signal-integrity constraints rather than additional insertion-loss figures. A practical design should include margin for connector condition, assembly tolerances and ageing while remaining below the 500 mW optical-power limit.

The driver must match the chosen speed variant and apply the pin polarities assigned to the required output channel. The regular version uses 3 V ±5%, draws up to 100 mA and accepts voltage or pulse driving, with a pulse width of up to 500 µs and a typical value of 300 µs. The ultra-fast version accepts 3–7.5 V, draws up to 350 mA and requires pulse driving with a pulse width no greater than 200 µs. Each of the four paths uses a defined positive and negative state across Pins 1 to 4, so the control circuit should prevent unintended combinations during transitions. The switch is described as latching, but no quiescent-current value is specified; this should be confirmed before finalising the power budget.

The input and output termination fields can be selected independently from no connector, FC/APC, FC/PC, SC/APC, SC/PC, ST, LC/UPC and LC/APC. Pigtails are available as bare fibre or in 900 µm loose tube, allowing the mechanical interface to be matched to internal assembly or panel-level connection requirements. Standard length codes cover 0.75 m and 1.0 m, with other lengths available by request. The 900 µm loose-tube option is limited to a maximum length of 2 m, which may affect enclosure placement and cable routing. Connector losses are not included in the optical ratings, so the chosen termination must also be included in the link-loss and return-loss assessment.

The 1 × 4 routing arrangement is intended for optical network protection and restoration, signal routing, configurable optical add/drop functions, transmitter and receiver protection, network test systems and instrumentation. The ultra-fast version can change path in 2–20 µs, while the regular version provides 50–200 µs switching for applications with less demanding timing. Repeatability of ±0.01 dB can support consistent measurements when test sequences repeatedly return to the same path. Channel crosstalk of at least 30 dB and PER of at least 18 dB must still be assessed against the required signal isolation and polarisation quality. The application must also remain within the 500 mW optical-power limit and the –5 to +70 °C operating range.