Fused Coupler Multimode 850 / 1310 / 1550 nm Standard / Wideband

The MMS / MMW multimode fused coupler is an optical power-splitting component for 50/125 µm or 62.5/125 µm multimode fibre systems. It can be ordered for a selected operating wavelength of 850, 1310 or 1550 nm, with standard MMS and wideband MMW type codes. Port arrangements include 1×2, 2×2, 1×3, 1×4 and 1×8 designs for different tapping, splitting and distribution requirements. Typical applications include local area networks, CATV systems, subscriber loops, fibre-optic instruments and fibre sensing assemblies. Balanced and unbalanced coupling ratios from 50:50 to 5:95 support equal splitting or controlled power extraction. Compact stainless-steel tubes and enclosed case packages are available with bare-fibre, loose-tube, jacketed and connectorised pigtail options.

Fused Coupler Multimode 850 / 1310 / 1550 nm Standard / Wideband

Range features

A high level overview of what this range offers

  • 850, 1310 or 1550 nm wavelength options: Match the coupler to the intended optical system.
  • MMS standard and MMW wideband types: Select between two ordering categories for different spectral requirements.
  • 1×2, 2×2, 1×3, 1×4 and 1×8 configurations: Support tapping, splitting and multi-channel distribution layouts.
  • 50/125 µm and 62.5/125 µm fibre options: Provide compatibility with common multimode fibre sizes.
  • Low insertion-loss specifications: Help control the coupler’s contribution to the optical power budget.
  • At least 35 dB directivity: Provides a defined level of isolation between relevant optical paths.
  • Balanced and unbalanced coupling ratios: Enable equal splitting or controlled power extraction from the main path.
  • Tube and case package choices: Accommodate compact assemblies and enclosed installations.
  • Multiple pigtail and connector formats: Simplify integration into spliced or connectorised fibre systems.
  • Extended operating temperature available on request: Supports specified operation from −40 to +85 °C when requested.

Downloads

for Fused Coupler Multimode 850 / 1310 / 1550 nm Standard / Wideband

pdf
Multimode Fused Coupler Datasheet
Download

What’s in this range?

All the variants in the range and a comparison of what they offer

Performance specifications

Parameter1×2/2×2, grade P1×2/2×2, grade A1×3, grade P1×4, grade P1×8, grade P

Operating wavelength

850, 1310 or 1550 nm

850, 1310 or 1550 nm

850, 1310 or 1550 nm

850, 1310 or 1550 nm

850, 1310 or 1550 nm

Insertion loss, 50/125 µm fibre

≤3.5 dB

≤3.7 dB

≤6.0 dB

≤7.2 dB

≤10.5 dB

Insertion loss, 62.5/125 µm fibre

≤4.0 dB

≤4.2 dB

≤6.5 dB

≤7.6 dB

≤11.0 dB

Uniformity

≤0.60 dB

≤0.80 dB

≤1.2 dB

≤1.2 dB

≤2.0 dB

Directivity

≥35 dB

≥35 dB

≥35 dB

≥35 dB

≥35 dB

Operating temperature

−20 to +75 °C; −40 to +85 °C available on request

−20 to +75 °C; −40 to +85 °C available on request

−20 to +75 °C; −40 to +85 °C available on request

−20 to +75 °C; −40 to +85 °C available on request

−20 to +75 °C; −40 to +85 °C available on request

Storage temperature

−40 to +85 °C

−40 to +85 °C

−40 to +85 °C

−40 to +85 °C

−40 to +85 °C

Available package types

A, M or C

A, M or C

A or C

S or D

D

Package dimensions

A: Ø3.0 × 54 mm, or 60 mm with 900 µm pigtail; M: Ø3.0 × 40 mm; C: 98 × 14 × 8.5 mm

A: Ø3.0 × 54 mm, or 60 mm with 900 µm pigtail; M: Ø3.0 × 40 mm; C: 98 × 14 × 8.5 mm

A: Ø3.0 × 54 mm, or 60 mm with 900 µm pigtail; C: 98 × 14 × 8.5 mm

S: 89 × 51 × 9.2 mm; D: 120 × 80 × 11.6 mm

D: 120 × 80 × 11.6 mm

Package construction

A and M: stainless-steel tube; C: case

A and M: stainless-steel tube; C: case

A: stainless-steel tube; C: case

Case

Case

Performance values are measured under stable-mode conditions using an LED source with CPR below 12. The listed optical values exclude connector loss.

Unbalanced 1×2 insertion loss

Coupling ratioTop-port insertion lossMain-port insertion loss

5:95

14.5 dB

0.70 dB

10:90

11.2 dB

0.90 dB

20:80

7.8 dB

1.4 dB

30:70

6.0 dB

2.1 dB

40:60

4.7 dB

2.7 dB

Ordering sequence: Type → Grade → Wavelength → Coupling ratio → Port → Package → Fibre type → Pigtail style → Fibre length → Input connector → Output connector

Ordering scheme

Order-code segmentAvailable codes and meanings

Type

MMS = standard; MMW = wideband

Grade

P = P grade; A = A grade

Wavelength

85 = 850 nm; 31 = 1310 nm; 55 = 1550 nm

Coupling ratio

50 = 50:50; 40 = 40:60; 30 = 30:70; 20 = 20:80; 10 = 10:90; 05 = 5:95

Port

102 = 1×2; 202 = 2×2

Package

A = A package; M = M package; C = C package; S = S package; D = D package

Fibre type

A = 50/125 µm; B = 62.5/125 µm

Pigtail style

1 = bare fibre; 2 = 900 µm loose tube; 3 = 3 mm jacket; 4 = 2 mm jacket; 5 = 1.6 mm jacket

Fibre length

05 = 0.5 m; 10 = 1.0 m; 20 = 2.0 m

Input connector

0 = none; 1 = FC/APC; 2 = FC/PC; 3 = SC/APC; 4 = SC/PC; 5 = ST; 6 = LC/UPC; 7 = LC/APC

Output connector

0 = none; 1 = FC/APC; 2 = FC/PC; 3 = SC/APC; 4 = SC/PC; 5 = ST; 6 = LC/UPC; 7 = LC/APC

Other fibre lengths are available on request. The 900 µm loose-tube option is limited to a maximum length of 2 m.

FAQs

for Fused Coupler Multimode 850 / 1310 / 1550 nm Standard / Wideband

Use MMS when the application requires the standard type and MMW when a wideband implementation is needed. Both types can be ordered for a nominal wavelength of 850, 1310 or 1550 nm. However, no numerical passband, usable wavelength span or wavelength-dependent insertion-loss limits are specified for the MMW version. It should therefore not be assumed that one wideband device automatically covers all three nominal wavelengths. For multi-wavelength operation, confirm the required spectral response for the exact fibre size, coupling ratio, port configuration and package before completing the design.

Insertion loss increases as the number of output ports rises, so the configuration should be selected according to the power available at the source and the sensitivity required at each receiver. With 50/125 µm fibre, grade P limits are 3.5 dB for 1×2 or 2×2, 6.0 dB for 1×3, 7.2 dB for 1×4 and 10.5 dB for 1×8. The corresponding 62.5/125 µm limits are 4.0, 6.5, 7.6 and 11.0 dB. Grade A is available for 1×2 and 2×2 configurations, with limits of 3.7 dB for 50/125 µm fibre and 4.2 dB for 62.5/125 µm fibre. Connector, splice and fibre losses must be added separately when calculating the complete link budget.

The coupler can be ordered for either 50/125 µm or 62.5/125 µm fibre, but the fibre type is a defined order-code selection rather than an interchangeable field setting. The maximum insertion loss for 62.5/125 µm versions is generally 0.4 to 0.5 dB higher than for the equivalent 50/125 µm configuration. For example, the 1×4 grade P limits are 7.2 dB for 50/125 µm fibre and 7.6 dB for 62.5/125 µm fibre. Matching the coupler fibre to the installed link helps avoid core-size and modal compatibility issues. The complete system should therefore use a consistent fibre type wherever possible.

Select the coupling ratio according to the amount of power required at the tapped top port and the power that must remain on the main path. At 5:95, the listed insertion losses are 14.5 dB at the top port and 0.70 dB at the main port. Moving through 10:90, 20:80, 30:70 and 40:60 reduces the top-port loss to 11.2, 7.8, 6.0 and 4.7 dB, while main-port loss rises to 0.90, 1.4, 2.1 and 2.7 dB. These figures exclude connector loss. The final choice should allow for source variation, fibre attenuation, splices, connectors and receiver sensitivity on both optical paths.

The package choice depends partly on the port configuration and partly on the mechanical space available. The 1×2 and 2×2 versions support A, M and C packages, while the 1×3 version supports A and C; 1×4 uses S or D, and 1×8 uses D. The A package is a 3.0 mm diameter stainless-steel tube measuring 54 mm long, or 60 mm with a 900 µm pigtail, while the compact M package measures 3.0 mm in diameter by 40 mm long. Case dimensions are 98 × 14 × 8.5 mm for C, 89 × 51 × 9.2 mm for S and 120 × 80 × 11.6 mm for D. Allow additional space for pigtail bend radius, strain relief and connector access when planning the enclosure.

Pigtail formats include bare fibre, 900 µm loose tube and jacketed constructions with diameters of 1.6, 2 or 3 mm. Defined fibre-length codes cover 0.5, 1.0 and 2.0 m, with other lengths available on request; the 900 µm loose-tube option is limited to 2 m. Input and output terminations can be selected independently as unterminated, FC/APC, FC/PC, SC/APC, SC/PC, ST, LC/UPC or LC/APC. The connector polish must match the adjoining equipment, as APC and PC or UPC interfaces should not be directly mated. Connector losses are not included in the base optical specifications and must be added to the system budget.

The standard operating range is −20 to +75 °C, while operation from −40 to +85 °C is available on request. The specified storage range is −40 to +85 °C. Optical performance is defined under stable-mode conditions using an LED source with CPR below 12, which is relevant because multimode measurements can vary with the launch distribution. Systems using a VCSEL, laser or another launch condition should be validated with the intended source, fibre and receiver combination. Qualification should also include the selected connectors, pigtail construction, enclosure strain relief and expected temperature cycling.

Uniformity describes the permitted loss variation between output channels, while directivity indicates the level of isolation between relevant optical paths. The maximum uniformity is 0.60 dB for a grade P 1×2 or 2×2 coupler and 0.80 dB for the corresponding grade A version. Limits increase to 1.2 dB for 1×3 and 1×4 configurations and 2.0 dB for 1×8. Directivity is specified at a minimum of 35 dB across the range. Applications requiring closely matched receiver levels should account for the full uniformity limit rather than assuming identical output power at every port.