PLC Splitter High Power 1 W 1310 / 1550 / 1260-1650 nm
- Technology
- Passive optical components
- Partner
- AC Photonics
The H1PLC high-power PLC splitter is a passive planar lightwave circuit device for dividing one or two optical inputs across as many as 64 outputs. It is designed for FTTx networks, passive optical networks, local area networks, cable television systems and optical test equipment. The range supports optical power levels up to 1.0 W, with higher-power configurations available on request. Engineers can select narrow wavelength windows centred on 1310 nm or 1550 nm, a dual 1310/1550 nm option, or operation across 1260–1650 nm. Maximum insertion loss, uniformity, polarisation-dependent loss and wavelength-dependent loss are defined for each port configuration. Package choices include component, enclosed module, LGX box and 19-inch rack formats, together with several fibre, pigtail and connector options. An operating and storage temperature range of -40 to +85°C supports installation in temperature-variable environments.

Range features
A high level overview of what this range offers
- Optical power rating up to 1.0 W: Supports high-power optical distribution within the defined limit.
- 1×2 to 2×64 configurations: Provides a choice of single-input and dual-input splitting arrangements.
- Four wavelength selections: Covers 1310 nm, 1550 nm, dual-band and 1260–1650 nm applications.
- Maximum insertion loss from 4.0 to 22.2 dB: Provides defined values for optical link-budget calculations.
- Polarisation-dependent loss from 0.20 to 0.40 dB: Limits output variation associated with input polarisation.
- Return loss of at least 50 dB and directivity of at least 55 dB: Supports the control of unwanted optical reflections and channel coupling.
- Temperature-dependent loss of no more than 0.50 dB: Defines loss variation across the -40 to +85°C range.
- Multiple package and termination formats: Allows selection for component-level, module, LGX or rack integration.
- Telcordia GR-1221 and GR-1209 qualification: Provides an established environmental and reliability qualification basis.
- RoHS compliance: Supports material compliance requirements for electrical and optical equipment.
Downloads
for PLC Splitter High Power 1 W 1310 / 1550 / 1260-1650 nm
What’s in this range?
All the variants in the range and a comparison of what they offer
Specifications
| Specification | Value |
|---|---|
Operating wavelength options | 1310 ±40 nm; 1550 ±40 nm; 1310/1550 nm; 1260–1650 nm |
Port configurations | 1×2, 2×2, 1×4, 2×4, 1×8, 2×8, 1×16, 2×16, 1×32, 2×32, 1×64 and 2×64 |
Maximum optical power | ≤1.0 W; higher power available on request |
Temperature-dependent loss | ≤0.50 dB from -40 to +85°C |
Return loss | ≥50 dB |
Directivity | ≥55 dB |
Operating temperature | -40 to +85°C |
Storage temperature | -40 to +85°C |
Fibre options | SMF-28 Ultra G.657.A1; ClearCurve ZBL G.657.B3; SMF-28 G.652 available on request |
Pigtail styles | Bare fibre, 900 µm loose tube, 1.6 mm jacket, 2 mm jacket or 3 mm jacket |
Standard fibre lengths | 0.5 m, 1.0 m and 5.0 m; other lengths available on request; 900 µm loose tube limited to 2 m |
Connector options | None, FC/APC, FC/PC, SC/APC, SC/PC, ST, LC/UPC, LC/APC, 8-fibre MPO male or 8-fibre MPO female |
Package formats | Type A, S, F, G, H, single or double LGX box, and single or double 19-inch rack |
Qualification and compliance | Telcordia GR-1221, Telcordia GR-1209 and RoHS |
Optical test basis | Asterisked optical values apply at room temperature and exclude connector loss |
Variant Performance Comparison
| Parameter | 1×2 | 2×2 | 1×4 | 2×4 | 1×8 | 2×8 | 1×16 | 2×16 | 1×32 | 2×32 | 1×64 | 2×64 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Maximum insertion loss, dB | 4.0 | 4.5 | 7.2 | 7.8 | 10.8 | 11.2 | 14.0 | 14.5 | 16.9 | 17.5 | 21.0 | 22.2 |
Uniformity, dB | 0.50 | 1.2 | 0.60 | 1.2 | 0.80 | 1.5 | 1.2 | 2.0 | 1.7 | 2.5 | 2.5 | 2.5 |
Polarisation-dependent loss, dB | 0.20 | 0.30 | 0.20 | 0.30 | 0.30 | 0.40 | 0.30 | 0.40 | 0.30 | 0.40 | 0.30 | 0.40 |
Wavelength-dependent loss, dB | 0.30 | 0.30 | 0.30 | 0.40 | 0.30 | 0.60 | 0.50 | 0.60 | 0.80 | 0.80 | 0.80 | 1.0 |
Type A ribbon or bare-fibre package, L×W×H; unit not defined | 40×4×4 | 40×4×4 | 40×4×4 | 40×4×4 | 40×4×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×12×4 | 60×12×4 |
Type A 900 µm loose-tube package, L×W×H; unit not defined | 60×7×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×12×4 | 60×12×4 | 80×20×6 | 80×20×6 | 100×40×6 | 100×40×6 |
Ordering Scheme
| Order-code field | Code | Selection |
|---|---|---|
Type | H1PLC | High-power PLC splitter series |
Grade | P | P grade |
Operating wavelength | 31; 55; 3155; 2665 | 1310 nm; 1550 nm; 1310/1550 nm; 1260–1650 nm |
Port configuration | 102; 202; 104; 204; 108; 208; 116; 216; 132; 232; 164; 264 | 1×2; 2×2; 1×4; 2×4; 1×8; 2×8; 1×16; 2×16; 1×32; 2×32; 1×64; 2×64 |
Package | F; G; H; R1; R2; L1; L2; A | F package; G package; H package; single 19-inch rack; double 19-inch rack; single LGX box; double LGX box; A package |
Fibre type | 1; 2; 3 | SMF-28 G.652 on request; SMF-28 Ultra G.657.A1; ClearCurve ZBL G.657.B3 |
Pigtail style | 1; 2; 3; 4; 5 | Bare fibre; 900 µm loose tube; 3 mm jacket; 2 mm jacket; 1.6 mm jacket |
Fibre length | 05; 10; 50 | 0.5 m; 1.0 m; 5.0 m |
Input connector | 0; 1; 2; 3; 4; 5; 6; 7; 8; 9 | None; FC/APC; FC/PC; SC/APC; SC/PC; ST; LC/UPC; LC/APC; 8-fibre MPO male; 8-fibre MPO female |
Output connector | 0; 1; 2; 3; 4; 5; 6; 7; 8; 9 | None; FC/APC; FC/PC; SC/APC; SC/PC; ST; LC/UPC; LC/APC; 8-fibre MPO male; 8-fibre MPO female |
Output option | No suffix; P0; P1; P2 | Ribbon fibre; individual bare fibre; fanout; 900 µm loose tube |
FAQs
for PLC Splitter High Power 1 W 1310 / 1550 / 1260-1650 nm
The selection should follow the operating bands and whether the splitter must carry one band or several bands. The 1310 ±40 nm version covers 1270–1350 nm, while the 1550 ±40 nm version covers 1510–1590 nm; a dual 1310/1550 nm ordering option is also available. For equipment that must pass several access or test wavelengths through one component, the 1260–1650 nm option provides the widest defined range. In practice, select a centred wavelength version when the optical plan is fixed, and consider the dual-band or extended-range version when multi-band operation is required.
Use the maximum insertion-loss value for the exact input and output configuration rather than applying a generic PLC splitter allowance. Maximum insertion loss rises from 4.0 dB for 1×2 and 4.5 dB for 2×2 to 21.0 dB for 1×64 and 22.2 dB for 2×64. Uniformity also changes with the split ratio, ranging from 0.50 dB for 1×2 to 2.5 dB for the largest configurations. These figures apply at room temperature and exclude connector loss. Connector pairs, splices, fibre attenuation and the required engineering margin must therefore be added separately when calculating the received power at the weakest output.
The defined optical power limit is up to 1.0 W, while versions for higher power are available on request. Whether the 1.0 W value applies to each input or the aggregate launched power is not further defined, so that point should be confirmed for dual-input and customised configurations. A conservative design should treat 1.0 W as the maximum power applied to the splitter unless the selected build is explicitly approved otherwise. Connector loss is excluded from the optical performance values, and connector condition can be particularly important at elevated optical power. The complete assembly should therefore be assessed using its actual connectors, splices and operating wavelength.
The choice depends on whether the splitter will be integrated into equipment, a fibre-management enclosure or a rack system. Type A supports ribbon fibre, individual bare fibre, fanout and 900 µm loose-tube arrangements, while S, F, G and H provide enclosed module formats. L1 and L2 identify single and double LGX boxes, and R1 and R2 identify single and double 19-inch rack formats. Package availability varies with the port count, and some LGX arrangements are intended for small-form-factor connectors. Mechanical drawings and fibre-exit positions should be checked before fixing mounting points or defining enclosure clearances.
The available fibre selections include SMF-28 Ultra G.657.A1 and ClearCurve ZBL G.657.B3, with SMF-28 G.652 available on request. Pigtails can be supplied as bare fibre, 900 µm loose tube, or with 1.6 mm, 2 mm or 3 mm jackets. Bare-fibre and ribbon arrangements can suit internal splicing, while loose-tube or jacketed options can support routed connections where additional fibre protection is needed. Standard order lengths are 0.5 m, 1.0 m and 5.0 m, although the 900 µm loose-tube option is limited to 2 m. Selection should account for the existing fibre type, splice process, bend routing and available enclosure space.
Input and output connector selections include FC/APC, FC/PC, SC/APC, SC/PC, ST, LC/UPC and LC/APC, together with 8-fibre MPO male and female options. Unconnectorised versions can also be ordered for direct fusion splicing or custom termination. APC, PC and UPC interfaces should be matched to the adjoining equipment and the network’s return-loss requirements rather than mixed without an appropriate interface plan. The specified optical values exclude connector loss, so every mated pair must be added to the system loss budget. MPO selection should also account for gender, fibre count and the polarity arrangement used by the wider installation.
The operating and storage temperature ranges are both -40 to +85°C, with temperature-dependent loss limited to 0.50 dB across that range. Asterisked insertion loss, uniformity, polarisation-dependent loss, return loss and directivity values apply at room temperature and exclude connector loss. Qualification covers Telcordia GR-1221 and GR-1209, while RoHS compliance addresses restricted-material requirements. These figures provide a basis for component selection, but the finished assembly should still be assessed in its actual package, connector and fibre configuration. Project-level testing may also be needed where vibration, sealing, handling or installation conditions extend beyond the defined component data.