PPDD 1100-1650 nm 600 MHz Coaxial Analogue Photodiode

The PPDD 600 MHz coaxial analogue photodiode is a fibre-coupled detector for optical signals from 1100 to 1650 nm. It combines a responsive photodiode with a hermetic, industry-standard coaxial package and an SMF-28e single-mode fibre pigtail. A maximum bandwidth of 0.6 GHz makes it suitable for channel-monitoring functions and applications that do not require multi-gigahertz detection. Typical responsivity is 0.85 A/W at 1310 nm and 0.90 A/W at 1550 nm, both specified at 25 °C. Connector selection is handled through the model suffix, with SC/APC and FC/APC versions available. The device operates from -40 to +85 °C and is identified as RoHS compliant. Optional mounting brackets and custom fibre lengths allow the mechanical configuration to be adapted to the installation.

PPDD 1100-1650 nm 600 MHz Coaxial Analogue Photodiode

Range features

A high level overview of what this range offers

  • 1100–1650 nm optical range – Covers the specified 1310 nm and 1550 nm responsivity points.
  • 600 MHz maximum bandwidth – Supports WDM channel monitoring and low-speed digital detection.
  • 0.85 A/W at 1310 nm and 0.90 A/W at 1550 nm – Provides typical conversion figures for optical-interface calculations.
  • -0.5 to +0.5 dB RF flatness limit – Defines the permitted RF amplitude variation.
  • 1 nA maximum dark current – Helps establish the zero-light offset budget for the readout circuit.
  • 0.8 pF maximum capacitance – Supports input-capacitance planning for the external amplifier stage.
  • Hermetic coaxial package – Supports integration where a sealed detector package is required.
  • SMF-28e single-mode fibre pigtail – Provides a standard 1 m fibre connection with a 0.9 mm flame-retardant Hytrel coating.
  • SC/APC and FC/APC options – Allows the connector format to match the existing optical interface.
  • -40 to +85 °C operation – Accommodates equipment exposed to an extended temperature range.
  • Optional bracket and custom fibre lengths – Allows the mechanical arrangement to be adapted to the enclosure.
  • RoHS compliant construction – Assists with applicable materials-compliance requirements.

Downloads

for PPDD 1100-1650 nm 600 MHz Coaxial Analogue Photodiode

pdf
PPDD Photodiode Module Datasheet
Download

What’s in this range?

All the variants in the range and a comparison of what they offer

Electro-optical characteristics

ParameterSymbolMinimumTypicalMaximumUnit

Operating temperature

T_OP

-40

—

+85

°C

Optical wavelength range

—

1100

—

1650

nm

Responsivity

R

—

0.85 at 1310 nm; 0.90 at 1550 nm

—

A/W

Bandwidth

BW

—

—

0.6

GHz

RF flatness

FR

-0.5

—

+0.5

dB

Dark current

I_D

—

—

1

nA

Capacitance

C

—

—

0.8

pF

Values apply at 25 °C unless otherwise stated.

Maximum ratings

ParameterSymbolLimit

Storage temperature

T_ST

-40 to +85 °C

Input power saturation

P_IN

10 mW

Reverse voltage

V_R

35 V

Forward current

I_F

10 mA

Mechanical configuration

  • Hermetically sealed, industry-standard coaxial package.
  • SMF-28e single-mode optical fibre with flame-retardant Hytrel coating.
  • Standard pigtail diameter: 0.9 mm.
  • Standard pigtail length: 1 m.
  • Custom fibre lengths and optional mounting brackets are available.
  • Lead orientation within the optional mounting bracket is arbitrary.

Model code and connector options

Complete modelConnector

PPDD-S

SC/APC

PPDD-F

FC/APC

Ordering format: PPDD-X, where the suffix identifies the optical connector. For example, PPDD-S specifies the PPDD module with an SC/APC connector, while PPDD-F specifies the FC/APC version.

FAQs

for PPDD 1100-1650 nm 600 MHz Coaxial Analogue Photodiode

Yes, the PPDD covers both 1310 nm and 1550 nm operation. Its specified optical wavelength range is 1100 to 1650 nm, with typical responsivity of 0.85 A/W at 1310 nm and 0.90 A/W at 1550 nm at 25 °C. At 1 mW incident power, those nominal figures correspond to approximately 0.85 mA and 0.90 mA of photocurrent before external circuit effects. The difference should be included in calibration, alarm thresholds or channel-comparison logic. No wavelength-response curve or tolerance around the typical responsivity is defined, so absolute power-measurement designs should include unit-level calibration.

The 0.6 GHz figure is the maximum detector bandwidth, not an automatic guarantee of 600 MHz system bandwidth. The photodiode capacitance is 0.8 pF maximum and RF flatness is limited to -0.5 to +0.5 dB, but the load impedance, reverse-bias condition and flatness frequency span are not defined. A transimpedance amplifier, PCB layout, bias network and connector transition must therefore be selected as one signal path. For low-speed digital use, verify rise time, threshold margin and noise in the completed assembly rather than relying on the detector figure alone. Parasitic capacitance and amplifier stability can reduce the usable bandwidth below the stated device limit.

An amplified voltage output is not specified, so the PPDD should be integrated as a photodiode current source. Responsivity is stated in A/W, while dark current is limited to 1 nA and capacitance to 0.8 pF; no transimpedance gain, output swing, supply voltage or load condition is defined. The external readout stage should therefore convert photocurrent to the voltage range required by the following ADC, comparator or monitoring circuit. Its input capacitance and feedback network will influence both stability and achievable bandwidth. Include offset handling for dark current and protection that keeps the detector within its optical and electrical maximum ratings.

The connector suffix defines the variant: PPDD-S uses SC/APC and PPDD-F uses FC/APC. Both variants use a single-mode fibre pigtail and share the stated detector characteristics, so selection mainly depends on the mating interface, panel layout and maintenance practice. The patch lead and adaptor should match the selected APC connector format. Connector return loss and insertion loss are not defined, so any system-level optical-loss budget should use separately qualified interconnect data. Custom fibre lengths are available, allowing the pigtail route to be fixed before the final model is ordered.

Keep incident optical power below the 10 mW input power saturation limit and reverse voltage below 35 V under normal operation, start-up and fault conditions. Forward current must also remain below 10 mA, which matters during incorrect biasing, power sequencing or protection-diode conduction. These are maximum ratings rather than recommended operating points, and no nominal reverse-bias voltage is specified. The bias supply should therefore include current limiting and transient control suitable for the receiver circuit. Where optical bursts or hot-plug events are possible, check peak power at the detector rather than relying only on average channel power.

The detector is hermetically housed in an industry-standard coaxial package and supplied with SMF-28e single-mode fibre. The standard pigtail has a flame-retardant Hytrel coating, a 0.9 mm diameter and a 1 m length, while custom lengths and an optional mounting bracket are available. Lead orientation within the optional bracket is arbitrary, so electrical identification should be confirmed during assembly rather than inferred from bracket position. The fibre route should include appropriate strain relief and bend control, particularly near the package entry. Enclosure clearances should be checked against the mechanical drawing because its dimensional values are not reproduced in the tabulated specifications.

The specified operating range is -40 to +85 °C, and the storage range is also -40 to +85 °C. This permits the same stated temperature limits to be used for powered operation, transport and unpowered storage, provided all other ratings are respected. The module is also identified as RoHS compliant. Humidity, condensation, shock, vibration, ingress protection and thermal-cycling ratings are not defined, so those conditions require system-level qualification. For exposed or mobile installations, the enclosure and mounting arrangement should provide the environmental protection that is not specified at module level.