The TEGAM 900 Series thermocouple thermometers provides a versatile range of rugged handheld instruments for precise temperature measurement in industrial, maintenance, and laboratory applications. The series includes standard digital models, Bluetooth-enabled data logging models, and intrinsically safe versions for hazardous areas. Single-channel and dual-channel options are available, with dual-input units supporting simultaneous two-point measurement and temperature differential display. Depending on the model, the instruments support up to eight thermocouple types for broad application flexibility across low and high temperature ranges.

Select 931B and 932B models add wireless data logging with storage for up to 1000 readings and Bluetooth Low Energy connectivity for transfer to mobile devices or PCs. The 921B and 922B models are designed for hazardous environments and offer intrinsically safe operation for use where flammable gases or dust may be present. Across the range, users benefit from high accuracy, probe offset adjustment, on-demand statistical functions, and long battery life using standard AA batteries. The sealed ergonomic housing is built for one-handed use and resists demanding field conditions. With a recommended 2-year calibration cycle and durable construction, the 900 Series is designed for reliable long-term use.

Thermocouple Thermometers

The TEGAM 900 Series thermocouple thermometers is designed for professionals who need dependable handheld temperature measurement across industrial, scientific, and field environments. The range combines rugged construction, simple one-handed operation, and strong measurement performance in a family of instruments that includes standard digital, intrinsically safe, and wireless data logging models.

Whether the application involves routine maintenance, hazardous-area inspection, process verification, or traceable temperature recording, the 900 Series offers a model suited to the task. Users can choose between single-input and dual-input versions, with advanced models supporting expanded thermocouple compatibility, Bluetooth data transfer, and internal logging for streamlined reporting and analysis.

Range features

A high level overview of what this range offers

  • Rugged ergonomic housing: Heavy-duty sealed construction resists dust, chemicals, shock, and daily industrial handling while remaining comfortable for one-handed use.
  • Single- and dual-channel options: Choose one- or two-input models for direct point measurement or simultaneous comparison with on-screen differential temperature display.
  • Broad thermocouple compatibility: Depending on model, supports J, K, T, E, N, R, S, and B thermocouple types for flexible use across many applications.
  • High measurement accuracy: Delivers precise readings at ±0.04% of reading + 0.3 °C for reliable process monitoring and quality assurance.
  • Wireless data logging on select models: The 931B and 932B provide Bluetooth Low Energy connectivity and storage for up to 1000 readings to simplify traceable data collection.
  • Intrinsically safe models available: The 921B and 922B are built for hazardous environments where safe operation around flammable gases or dust is required.
  • Long battery runtime: Standard digital and intrinsically safe models operate for up to 2000 hours, while data logging models run for around 1000 hours on three AA batteries.
  • On-demand statistics: View MIN, MAX, AVG, range, and standard deviation directly on the display for immediate process insight.
  • Probe offset adjustment: Compensate for known sensor deviation to improve overall measurement accuracy with a specific thermocouple probe.
  • Extended calibration interval: A recommended 2-year calibration cycle helps reduce maintenance frequency and downtime.

Downloads

for Thermocouple Thermometers

pdf
911B/912B Digital Thermocouple Thermometers Datasheet
Download
pdf
921B/922B Intrinsically Safe Thermocouple Thermometers Datasheet
Download
pdf
931B/932B Datalogging Thermocouple Thermometers Datasheet
Download

What’s in this range?

All the variants in the range and a comparison of what they offer

Specification911B (Digital)912B (Digital)921B (Intrinsically Safe)922B (Intrinsically Safe)931B (Datalogging)932B (Datalogging)

Input Channels

1

2

1

2

1

2

Thermocouple Types

K, J, T, E

K, J, T, E

K, J, T, E, N, R, S, B

K, J, T, E, N, R, S, B

K, J, T, E, B, N, R, S

K, J, T, E, B, N, R, S

Temperature Range

–250 to 1372 °C (–418 to 2502 °F)

–250 to 1372 °C (–418 to 2502 °F)

–250 to 1767 °C (–418 to 2502 °F)

–250 to 1767 °C (–418 to 2502 °F)

–250 to 1767 °C (–418 to 3308 °F)

–250 to 1767 °C (–418 to 3308 °F)

Accuracy

±0.04% rdg + 0.3 °C

±0.04% rdg + 0.3 °C

±0.04% rdg + 0.3 °C

±0.04% rdg + 0.3 °C

±0.04% rdg + 0.3 °C

±0.04% rdg + 0.3 °C

Resolution

0.1°/1° (auto)

0.1°/1° (auto)

0.1°/1° (auto)

0.1°/1° (auto)

0.1°/1° (auto)

0.1°/1° (auto)

Intrinsically Safe

No

No

Yes

Yes

No

No

Wireless (Bluetooth)

No

No

No

No

Yes (BLE 4.0)

Yes (BLE 4.0)

Data Logging Memory

No

No

No

No

1000 readings

1000 readings

Battery Life

~2000 hours

~2000 hours

~2000 hours

~2000 hours

~1000 hours

~1000 hours

Power Supply

3× AA batteries (user-replaceable) for all models

3× AA batteries (user-replaceable) for all models

3× AA batteries (user-replaceable) for all models

3× AA batteries (user-replaceable) for all models

3× AA batteries (user-replaceable) for all models

3× AA batteries (user-replaceable) for all models

Features & Functions of the TEGAM 911B & 912B Thermocouple Thermometers

FAQs

for Thermocouple Thermometers

The supported thermocouple types depend on the model. The 911B and 912B digital thermometers support K, J, T, and E. The 921B/922B intrinsically safe models and 931B/932B data logging models extend compatibility to additional high-temperature types including B, N, R, and S, giving broader coverage for demanding applications.

The 900 Series is specified at ±0.04% of reading + 0.3 °C, making it suitable for quality-critical measurement tasks. The instruments also include a probe offset function, allowing users to compensate for known probe-related error and improve overall system accuracy.

The 921B and 922B are the intrinsically safe models in the range. They are intended for use in hazardous locations where flammable gases, vapours, or dust may be present, making them appropriate for applications such as petrochemical facilities, fueling areas, and similar environments.

The 931B and 932B include internal memory for up to 1000 readings and Bluetooth Low Energy connectivity. This allows users to record measurements directly on the device and transfer or stream data to a compatible mobile device or PC for analysis, record keeping, and reporting.

Dual-channel models such as the 912B, 922B, and 932B can monitor two temperature points at the same time. They also provide a temperature difference display, which is especially useful for comparative diagnostics, inlet/outlet checks, and process efficiency evaluations.

The probe offset function allows users to enter a known correction value for a thermocouple probe. This helps compensate for minor sensor deviation and aligns displayed readings more closely with a verified reference, which is valuable when tighter measurement control is required.

These instruments are designed for demanding industrial and laboratory use. The ergonomic sealed housing supports one-handed operation and is built to withstand routine exposure to dust, chemicals, shocks, and general field handling, helping maintain reliability in harsh working conditions.

All models are powered by three standard AA batteries. The standard digital and intrinsically safe versions provide around 2000 hours of operation, while the Bluetooth data logging versions provide around 1000 hours, supporting long service intervals between battery changes.

The recommended calibration interval for the 900 Series is 2 years under normal use. This extended cycle helps reduce maintenance downtime while supporting confidence in long-term measurement performance. Optional accredited calibration services may also be available when documented traceability is required.