TPDM-x-y-z 1100-1650 nm 600 MHz Coaxial Monitor Photodiode Module

The TPDM-X-Y-Z is an InGaAs monitor photodiode module designed to sample optical signals while retaining a through path between its input and output pigtails. Its photodiode is sensitive across the 1100–1650 nm communications wavelength range, with electro-optical characteristics specified for C/L-band operation. Typical applications include optical amplifier gain monitoring, WDM channel supervision and general optical network monitoring. Tap ratios of 1%, 2%, 5% and 10% allow engineers to balance the available monitoring signal against through-path insertion loss. Fibre options include 250 µm bare fibre and 900 µm loose tube, with SC, FC and LC connector choices or unterminated pigtails. The detector is housed in a hermetically sealed, industry-standard coaxial package and uses two standard SMF-28 optical fibre pigtails. An operating temperature range of 0 to +75 °C supports integration into telecommunications and optical monitoring equipment operating within these limits.

TPDM-x-y-z 1100-1650 nm 600 MHz Coaxial Monitor Photodiode Module

Range features

A high level overview of what this range offers

  • InGaAs photodiode with 1100–1650 nm sensitivity: Supports optical monitoring across the stated communications wavelength range.
  • Integrated optical fibre tap: Provides a sampled detector signal while maintaining an optical through path.
  • 1%, 2%, 5% and 10% tap ratios: Allows the monitoring signal and through-path insertion loss to be balanced for the application.
  • 600 MHz RF bandwidth: Supports monitor signal processing at frequencies up to the stated bandwidth.
  • Maximum insertion loss from 0.2 to 0.9 dB: Provides defined link-budget values for each available tap ratio.
  • Minimum return loss of 45 dB: Helps limit reflected optical power within the monitored path.
  • Maximum PDL of 0.1 dB and WDL of 0.3 dB: Limits sensitivity to polarisation and wavelength changes under the stated conditions.
  • Hermetically sealed coaxial package: Provides a compact and protected detector construction.
  • Bare-fibre, loose-tube and connector options: Supports different assembly, handling and optical interface requirements.
  • RoHS and Telcordia compliance: Supports projects that require these declared compliance characteristics.

Downloads

for TPDM-x-y-z 1100-1650 nm 600 MHz Coaxial Monitor Photodiode Module

pdf
TPDM Monitor Photodiode Module Datasheet – Revision 1.5
Download

What’s in this range?

All the variants in the range and a comparison of what they offer

Electro-optical values apply at 25 °C unless otherwise specified and exclude connector effects.

Electro-optical and mechanical specifications

CategoryParameterSymbolSpecificationUnit / condition

Optical

Sensitivity wavelength range

—

1100–1650

nm

Optical

Characterised optical band

—

C/L band

—

Electrical

RF bandwidth

—

0.6

GHz, equivalent to 600 MHz

Optical

Responsivity, 1% tap

R

7–12 typical

mA/W

Optical

Responsivity, 2% tap

R

14–24 typical

mA/W

Optical

Responsivity, 5% tap

R

35–65 typical

mA/W

Optical

Responsivity, 10% tap

R

70–120 typical

mA/W

Optical

Insertion loss, 1% tap

FR

0.2 maximum

dB

Optical

Insertion loss, 2% tap

FR

0.4 maximum

dB

Optical

Insertion loss, 5% tap

FR

0.6 maximum

dB

Optical

Insertion loss, 10% tap

FR

0.9 maximum

dB

Optical

Return loss

—

45 minimum

dB

Optical

Wavelength-dependent loss

WDL

0.3 maximum

dB

Optical

Polarisation-dependent loss

PDL

0.1 maximum

dB

Electrical

Dark current

I_D

1 maximum

nA

Environmental

Operating temperature

T_OP

0 to +75

°C

Maximum rating

Storage temperature

T_ST

−40 to +85

°C

Maximum rating

Input power saturation

P_IN

100

mW

Maximum rating

Reverse voltage

V_R

35

V

Maximum rating

Forward current

I_F

10

mA

Mechanical

Optical fibre

—

Standard SMF-28

—

Mechanical

Pigtail arrangement

—

Two pigtails, input and output

—

Mechanical

Pigtail length

—

1

m

Compliance

Declared compliance

—

RoHS and Telcordia

Specific standard revisions not defined

Ordering scheme: TPDM-X-Y-Z

Code segmentSelectionCodeOption

X

Tap ratio

01

1%

X

Tap ratio

02

2%

X

Tap ratio

05

5%

X

Tap ratio

10

10%

Y

Fibre type

1

250 µm bare fibre

Y

Fibre type

2

900 µm loose tube

Z

Connector

1

SC/APC

Z

Connector

2

SC/UPC

Z

Connector

3

FC/APC

Z

Connector

4

FC/UPC

Z

Connector

5

LC/UPC

Z

Connector

6

No connector

Ordering example: A 5% tap with 900 µm loose tube and SC/APC termination uses X=05, Y=2 and Z=1, producing the order code TPDM-05-2-1.

FAQs

for TPDM-x-y-z 1100-1650 nm 600 MHz Coaxial Monitor Photodiode Module

The tap ratio should be selected by balancing the required monitor photocurrent against the insertion loss permitted in the main optical path. At 25 °C without connectors, typical responsivity rises from 7–12 mA/W at 1% to 14–24 mA/W, 35–65 mA/W and 70–120 mA/W at 2%, 5% and 10% respectively. Maximum insertion loss increases correspondingly from 0.2 dB to 0.4 dB, 0.6 dB and 0.9 dB. Lower tap ratios suit links with limited optical margin, provided the receiving electronics can resolve the smaller photocurrent. Calculate the expected current at the lowest monitored optical power and verify that the selected ratio remains within the worst-case link-loss budget.

The module is suitable when the monitoring path requires an electrical response up to 600 MHz rather than direct recovery of a multi-gigabit data stream. This bandwidth is intended for functions such as amplifier gain monitoring, WDM channel supervision and network condition monitoring. Overall circuit bandwidth will also depend on detector loading, bias components, PCB parasitics and the selected transimpedance amplifier. Photodiode capacitance, rise time and a recommended reverse-bias operating point are not defined, so full-bandwidth performance should be confirmed in the intended front-end circuit. The PCB layout and amplifier selection should therefore be designed around the complete 600 MHz signal chain rather than the detector rating alone.

The InGaAs photodiode is sensitive from 1100 to 1650 nm, while its electro-optical characteristics identify C/L-band operation. This makes the module directly relevant to optical communications monitoring in these commonly used wavelength bands. Each unit has two standard SMF-28 pigtails with a nominal length of 1 m, and the order code provides a choice between 250 µm bare fibre and 900 µm loose tube. SC/APC, SC/UPC, FC/APC, FC/UPC and LC/UPC connector options are available, as well as unterminated pigtails. Because the electro-optical figures exclude connectors, the selected connector loss and return-loss behaviour should be included separately in the system budget.

The design must keep optical input power within the 100 mW saturation rating, reverse voltage within 35 V and forward current within 10 mA. These figures are maximum ratings rather than recommended operating points, so normal operation should include suitable engineering margin. Dark current is specified at a maximum of 1 nA at 25 °C, which should be considered alongside amplifier input noise when estimating the lowest detectable signal. The permitted operating temperature is 0 to +75 °C, while the storage range extends from −40 to +85 °C. Bias protection, current limiting and optical overload behaviour should be reviewed before connecting the module to high-power amplifiers or test systems.

These parameters define how the fibre tap can influence the optical signal continuing through the module. Maximum insertion loss ranges from 0.2 dB for the 1% tap to 0.9 dB for the 10% tap, so the selected ratio must be included in the worst-case path-loss calculation. Minimum return loss is 45 dB, while wavelength-dependent loss and polarisation-dependent loss are limited to 0.3 dB and 0.1 dB respectively. The WDL and PDL figures help quantify possible variation as wavelength and input polarisation change. All of these values exclude connectors, so connector losses, reflections and tolerances must be added when calculating the complete installed link.

The order code uses three configurable segments covering tap ratio, fibre construction and connector type. Segment X uses 01, 02, 05 or 10 for tap ratios of 1%, 2%, 5% or 10%, while segment Y uses 1 for 250 µm bare fibre or 2 for 900 µm loose tube. Segment Z selects SC/APC, SC/UPC, FC/APC, FC/UPC, LC/UPC or no connector using codes 1 to 6. For example, a 5% tap with 900 µm loose tube and SC/APC termination uses X=05, Y=2 and Z=1, resulting in TPDM-05-2-1. The ordering scheme does not define different connectors for the input and output, so applications requiring mixed terminations should be checked before ordering.

The module combines a hermetically sealed coaxial detector package with two 1 m SMF-28 fibre pigtails. The input fibre is uncoloured and the output fibre is yellow, providing a visual method of distinguishing the optical direction during assembly. The electrical interface uses PD+, PD− and GND leads, and the lead orientation is indicated as arbitrary, so polarity and connection functions should be verified when designing the PCB footprint. The 900 µm loose-tube option provides more physical protection than the 250 µm bare-fibre version, while the bare-fibre option can suit compact internal routing. Suitable strain relief, bend-radius control and protection from pulling or twisting loads should be included in the mechanical design.