MCT (HgCdTE) Infrared Detectors

MCT detectors offer the highest sensitivity of all IR detectors in the range of 2 – 25 microns. These detectors can be offered either TE, liquid nitrogen, or cooled with a Stirling motor.

MCT (HgCdTE) Infrared Detectors

TE-cooled MCT detectors

Infrared Associates detectors consist of photoconductive MCT (HgCdTe) sensors mounted on two, three, or four-stage thermoelectric coolers. The standard IR detectors are optimised for wavelength ranges from 2μm to 5μm.

Extended range TE-cooled MCT detectors can be used for ranges up to 10 microns.

To improve the detection efficiency of these devices, optically enhanced MCT detectors with reflective and refractive optical elements are also available. The apparent improved sensitivity and D* of the test detectors is due to the ability of the optical components to focus the energy that would not normally hit the detector on the detector element. These detectors are particularly suitable for applications where the energy either collimates or diverges. The optically enhanced detectors are therefore ideal for applications where fibre optics are used.

ModelElement Size (mm)WavelengthD(λp.10000.1) 2-stage TE cooledD(λp.10000.1) 3-stage TE cooledD(λp.10000.1) 4-stage TE cooled

MCT-3.5-TE-0.25

0.25 x 0.25

2 – 3.5µm

> 1.0E11

Not available

Not available

MCT-3.5-TE-1.00

1.00 x 1.00

2 – 3.5µm

> 2.0E10

Not available

Not available

MCT-5-TE-0.10

0.10 x 0.10

2 – 5µm

> 1.0E11

> 4.0E10

> 6.0E10

MCT-5-TE-0.50

0.50 x 0.50

2 – 5µm

> 1.0E11

> 4.0E10

> 6.0E10

MCT-5-TE-1.00

1.00 x 1.00

2 – 5µm

> 1.0E11

> 4.0E10

> 6.0E10

MCT-5-TE-2.00

2.00 x 2.00

2 – 7µm

Not available

> 3.0E10

> 4.0E10

MCT-7-TE-0.25

0.25 x 0.25

2 – 7µm

Not available

> 1.0E10

> 1.5E10

MCT-7-TE-1.00

1.00 x 1.00

2 – 7µm

Not available

> 1.0E10

> 1.5E10

MCT-9-TE-0.25

0.25 x 0.25

2 – 9µm

Not available

> 2.0E9

> 1.5E9

MCT-9-TE-1.00

1.00 x 1.00

2 – 9µm

Not available

> 2.0E9

> 1.5E9

Alternatively, optically enhanced TE-cooled HgCdTe detectors are available. Thanks to added reflective and refractive optics, the detectivity rating increases by a factor of 2 – 3.

Other wavelength ranges and element sizes available on request.

Downloads

for MCT (HgCdTE) Infrared Detectors

pdf
Infrared Associates TE cooled MCT detectors brochure
Download

Contact us

To request further information and availability please feel free to contact us right away.Or just fill out our contact form for a member of the sales team to respond to you.

Mandatory field: please enter your phone number.

In submitting this enquiry form you confirm you have read and agree to our privacy policy .

There was an error while sending the form. Please try again.