Current Transformers

When you need to measure current, several techniques are available in the industry. All have the same process. They convert the signal to measure at a standard level, which in turn permits the use of standard measurement instruments and relays.

Previously marketed under the name “Garre”, Noratel offers a comprehensive range of current transformers. Standard models are available as encapsulated versions (UL94-V0) in a range of different flavors all manufactured and tested according to IEN60044-1 (VDE 0414/1).

Current transformers can be supplied for primary currents from 10amps to 10000amps and accuracy classes from 0.1% and higher for specified burdens and overcurrent values.

They are cut for AC low-frequency measurements and system installations on bus bars or distribution cables.

In addition, customised solutions are possible in accordance with international standards (IEC, ANSI, and BS).

Current Transformers

Range features

A high level overview of what this range offers

Features
  • 50/ 60Hz operational frequencies
  • Two types are available: measuring for instruments/ protecting for relè
  • Tested according to IEN60044-1 (VDE 0414)
  • Alternatively IEEE Std C57.13-1993 (ANSI)
  • Moulded and encapsulated
  • Available with fastening brackets and sealable secondary housings
  • Class 0.2 – 3
  • Optional class 0.1 and 0.2S
General characteristics
  • Maximum operating voltage: 720V
  • Test voltage (1 min): 3KV
  • Continuous overcurrent: 1.2 x In
  • Thermal overcurrent (sec): Ith = 60 x In
  • Dynamic overcurrent Idyn = 2.5 x Ith
  • Insulation class (ta): E(120°C)

Downloads

for Current Transformers

pdf
Noratel current transformers class 0.2 brochure
Download
pdf
Noratel bar primary measuring
Download
pdf
Noratel wound primary measuring
Download
pdf
Noratel summation
Download
pdf
Noratel bar primary protection
Download

What’s in this range?

All the variants in the range and a comparison of what they offer

Standard modelsRatioClass/ burdenHoleDimensions

GK

250/ 5A – 600/ 5A

0.1/ 2 VA to 0.1/ 5VA

40 x 10mm 30 x15mm Ø 29mm

74 x 52 x 81mm

L60X

500/ 5A – 1500/ 5A

0.1/ 3 VA to 0.1/ 10VA

60 x 10mm 50 x 20mm 40 x 30mm

89 x 50 x 108mm

K100K

1000/ 5A – 3000 /5A

0.1/ 5VA

100 x 10mm 80 x 60mm

139 x 54 x 150mm

LGK

3000/ 5A – 4000/ 5A

0.1/ 5VA

120 x 35mm

170 x 54 x 140mm

Bar-primary measuringRatioClass/ burdenHoleDimensions

X21R 700

20/ 1A – 150/ 1A – 150/ 3A

3/ 0.4VA to 3/ 3VA

for cable ø 21

54 x 44 x 30mm

A205/70 653

1500/ 1A – 8000/ 1A – 8000/ 5A

0.2 – 15VA to 3/ 100VA

for busbar 205 x 70

240 x 240 x 55mm

Other 54 series

Wound-primary measuringRatioClass/ burdenDimensions

GP-1 401

0.1/ 1A – 15/ 1A – 15/ 5A

0.2/ 3VA to 5/ 5VA

81 x 74 x 52mm

LP-3 413

15/ 1A – 100/ 1A – 100/ 5A

0.2/ 7.5VA to 1/ 25VA

108 x 89 x 86mm

Other 7 series

SummationNumber of inputsClass/ burdenDimensions

UA 221

2 – 8

0.2/ 5VA – 1/ 40VA

120 x 120 x 53mm

Bar-primary protectionRatioBurden in class 10P5HoleDimensions

N33R 073

50/ 1A – 300/ 5A

3 – 17.5VA

for cable ø 33

117 x 99 x 48mm

Other 18 series

Contact us

To request further information and availability please feel free to contact us right away.Or just fill out our contact form for a member of the sales team to respond to you.

Mandatory field: please enter your phone number.

In submitting this enquiry form you confirm you have read and agree to our privacy policy .

There was an error while sending the form. Please try again.