Infrared Blackbody Sources

Lumasense’s Mikron® infrared blackbody calibration sources are highly accurate calibration equipment for pyrometers, thermal imaging cameras, radiometers, heat flux, and spectrographic measurement systems.

A long history of excellence:

  • Mikron® Infrared, started in 1969, was a leader and innovator in blackbody calibration sources, thermal imaging, and pyrometry
  • Mikron® blackbodies are still considered one of the most accurate, reliable blackbody brands on the market
  • Largest choice of flat plate sources and cavity sources
  • Largest choice of temperature ranges from -40°C to +3000°C
Infrared Blackbody Sources

Range features

A high level overview of what this range offers

  • Self-contained high-speed cameras
  • High-G rated high-speed cameras
  • Defence and airborne high-speed cameras
  • Customised high-speed cameras
  • Long-time recording systems
  • Accessories

Downloads

for Infrared Blackbody Sources

pdf
Lumasense Advanced Energy IR Blackbody overview catalogue
Download

Contact us

To request further information and availability please feel free to contact us right away.Or just fill out our contact form for a member of the sales team to respond to you.

Mandatory field: please enter your phone number.

In submitting this enquiry form you confirm you have read and agree to our privacy policy .

There was an error while sending the form. Please try again.

What’s in this range?

All the variants in the range and a comparison of what they offer

Mikron modelTemperature rangeMeasurement uncertaintyEmissivityHeated emitter shapeAperture diameterAverage warm-up time

IRC 35 through 150

Fixed temperature: 35°C, 45°C, 70°C, 75°C, 95°C, 100°C, 110°C, 120°C, 140°C, or 150°C

from 0.4°C (IRC 35) to 0.7°C (IRC 150)

0.98 +/-0.004 (from 2µm to 5.4µm, and from 8µm to 14µm)

Flat plate

50.8mm

Max. 5 (IRC 35) to 30 min (IRC150)

M310 HT

Ambient +5 to 450°C

0.25% of reading, +/-1°C

1.00 effective emissivity @ 8µm to 14µm

Flat plate

76mm

<30 min from ambient (to 400°C)

M300

200°C to 1150°C

0.25% of reading, +/-1°C

1.00 effective @ 0.65µm to 1.8µm

Spherical

51mm

1 hour from ambient to 1000°C

M330

300°C to 1700°C

0.25% of reading, +/-1°C

1.00 effective @ 0.65µm to 1.8µm – about 0.998µm for others

Heated cavity shape (field replaceable)

25mm

45 to 50 minutes from ambient to 300°C65 to 80 minutes from 300 to 1600°C

M335

300°C to 1500°C

±0.4% of reading ±1°C

1.00 at 0.65µm to 1.8µm

Cylindrical cavity

16.5mm

<30 min from ambient (to 1200°C)

M360

100°C to 1100°C

0.2% of reading, +/-1°C

1.00 effective @ 0.7µm to 1.8µm (T>230°C) and @ 8µm to 14µm (T<230°C)

Spherical

25.4mm

60 minutes from ambient to 700°C

M390

600°C to 3000°C

0.25% of reading, +/-1°C

1.0 between 0.65µm to 1.8µm

Graphite cavity (field replaceable)

25mm (16mm in option)

Only 5 minutes from ambient to 2300°C