Ultron Uninterruptible Power Supplies solutions
- Technology
- AC-AC uninterruptable power supplies
- Partner
- Delta Electronics
The Delta Ultron UPS family delivers high-efficiency online power protection for businesses of all sizes. Designed for mission-critical applications, Ultron UPSs ensure maximum reliability and stability for IT rooms, data centers, telecommunications, banking, and healthcare facilities.
The Ultron lineup includes the DPS Series, ranging from 160 to 1200 kVA with exceptional performance and efficiency; the HPH Series, covering 20 to 200 kW and delivering best-in-class power and cost savings; and the NT Series, with 20 to 500 kVA and flexible customization for scalable performance.
Ultron systems provide robust protection with advanced features such as dual input design, high energy efficiency, parallel expansion, three-phase PFC, and N+X redundancy.

Range features
A high level overview of what this range offers
- High-efficiency online UPS for reliable power protection
- Scalable power: 20 kW to 1200 kVA (DPS, HPH, NT Series)
- Dual input design and N+X redundancy for maximum uptime
- Parallel expansion and three-phase PFC for flexibility and stability
- Ideal for SMBs, data centers, telecom, banking, and healthcare
What’s in the range?
All the variants in the range and a comparison of what they offer
Product family | Models | Power rating | Input (voltage range) | Output (voltage range) | Operating temperature | Physical dimensions (W x D x H) |
---|---|---|---|---|---|---|
DPM Gen2 Series UPS, 300-2100 kVA, 480 Vac | DPM-300K / DPM-600K/ DPM-900K / DPM-1200K DPM-1500K / DPM-1800K / DPM-2100K | DPM-300K300 kVA / 300 kW DPM-600K600 kVA / 600 kW DPM-900K900 kVA / 900 kW DPM-1200K1200 kVA / 1200 kW DPM-1500K1500 kVA / 1500 kW DPM-1800K1800 kVA / 1800 kW DPM-2100K2100 kVA / 2100 kW | 408-552 Vac (100% load) | 480 Vac, 3P3W+PE | 0 to 40°C (32 to 104°F) | DPM-1200K3070 x 990 x 2000 mm (120.87 x 38.98 x 78.74 inch) DPM-1500K3400 x 990 x 2000 mm (133.86 x 38.98 x 78.74 inch) |
DPM Gen2 Series UPS, 250-1750 kVA | DPM-250K / DPM-500K / DPM-750K / DPM-1000K DPM-1250K / DPM-1500K/ DPM-1750K | DPM-250K250 kVA / 250 kW DPM-500K500 kVA / 500 kW DPM-750K750 kVA / 750 kW DPM-1000K1000 kVA / 1000 kW DPM-1250K1250 kVA / 1250 kW DPM-1500K1500 kVA / 1500 kW DPM-1750K1750 kVA / 1750 kW | 323-477 Vac (100% load) | 380/ 400/ 415 Vac, 3P3W+PE or 3P4W+PE | 0 to 40°C | DPM-250K1030 x 990 x 2000 mm DPM-1000K3070 x 990 x 2000 mm DPM-1250K3400 x 990 x 2000 mm |
DPM Series UPS, 250-1250 kVA, 480 Vac | DPM-250K / DPM-500K / DPM-750K / DPM-1000K / DPM-1250K | DPM-250K250 kVA / 250 kW DPM-500K500 kVA / 500 kW DPM-750K750 kVA / 750 kW DPM-1000K1000 kVA / 1000 kW DPM-1250K1250 kVA / 1250 kW | +10/-15%, 408~552 Vac (full load) | 480 Vac, 3P3W | 32~104°F (0~40°C) | DPM-250K59.6 x 34.4 x 74.8 in DPM-500K83.8 x 34.4 x 74.8 in DPM-750K108.1 x 34.4 x 74.8 in DPM-1000K153.9 x 34.4 x 74.8 in DPM-1250K178.2 x 34.4 x 74.8 in |
DPS Series UPS, Three Phase, 300/400/500/600/800/1000/1200 kVA | DPS-300K / DPS-400K / DPS-500K / DPS-600K DPS-800K / DPS-1000K / DPS-1200K | DPS-300K300 kVA / 300 kW DPS-400K400 kVA / 400 kW DPS-500K500 kVA / 500 kW DPS-600K600 kVA / 600 kW DPS-800K800 kVA / 800 kW DPS-1000K1000 kVA / 1000 kW DPS-1200K1200 kVA / 1200 kW | 176/304~276/478 Vac (full load) | 220/380 Vac, 230/400 Vac, 240/415 Vac (3-phase, 4-wire + G) | 0~40℃ | DPS-300K600 x 900 x 2000 mm DPS-400K/500K/600K1200 x 900 x 2000 mm DPS-800K1800 x 900 x 2000 mm DPS-1000K/1200K2450 x 900 x 2000 mm |
HPH Gen2 Series UPS, Three Phase, 20/30/40 kVA | HPH-20K / HPH-30K / HPH-40K | HPH-20K/B/B-N20 kVA / 20 kW HPH-30K/B/B-N30 kVA / 30 kW HPH-40K/B/B-N40 kVA / 40 kW | 305-478 Vac (full load), 228-305 Vac (with derating to 70-100%) | 220/380 Vac, 230/400 Vac, 240/415 Vac (3-phase, 4-wire + G) | 0 to 40 ℃ | 240 x 630 x 650 mm |
HPH Series UPS, Three Phase, 60/80/100/120 kW | HPH-60K, HPH-80K, HPH-100K, HPH-120K | HPH-60K60 kVA/kW HPH-80K80 kVA/kW HPH-100K100 kVA/kW HPH-120K120 kVA/kW | 332-477 Vac (full load) 228-332 Vac (with derating from 63-100% load) | 380/400/415 Vac, 3P4W+PE | 0 to 45˚C | HPH-60/80K520 x 800 x 1175 mm HPH-100/120K520 x 800 x 1760 mm |
HPH Series UPS, Three Phase, 160/200 kVA | HPH-160K, HPH-200K | HPH-160K160 kVA* / 150 kW HPH-200K200 kVA / 200 kW | 305-478 Vac (full load) 228-478 Vac (70% load) | 220/380 Vac, 230/400 Vac, 240/415 Vac (3-phase, 4-wire + G) | 0 to 40℃ | 600 x 1100 x 1600 mm |
IPT Series, Three Phase, 20-200 kVA | IPT-20K, IPT-30K, IPT-40K, IPT-50K, IPT-60K, IPT-80K, IPT-100K, IPT-120K, IPT-160K, IPT-200K | IPT-20K20 kVA / 18 kW IPT-30K30 kVA / 27 kW IPT-40K40 kVA / 36 kW IPT-50K50 kVA / 45 kW IPT-60K60 kVA / 54 kW IPT-80K80 kVA / 72 kW IPT-100K100 kVA / 90 kW IPT-120Kl120 kVA / 108 kW IPT-160K160 kVA / 144 kW IPT-200K200 kVA / 180 kW | 324-477 Vac (100% load), 286-324 Vac (with derating to 70-100% load) | 380/400/415 Vac, 3P4W+PE (3P3W+PE optional) | 0 to 40°C | IPT-20K-80K600 x 830 x 1420 mm IPT-100K/120K800 x 830 x 1570 mm IPT-160K/200K1200 x 830 x 1700 mm |
NT Series, Three Phase, 20-500 kVA | NT-20K, NT-30K, NT-40K, NT-50K, NT-60K, NT-80K, NT-100K NT-120K, NT-160K, NT-200K, NT-260K, NT-320K, NT-400K, NT-500K | NT-20K20 kVA / 16 kW NT-30K30 kVA / 24 kW NT-40K40 kVA / 32 kW NT-50K50 kVA / 40 kW NT-60K60 kVA / 48 kW NT-80K80 kVA / 64 kW NT-100K100 kVA / 80 kW NT-120K120 kVA / 96 kW NT-160K160 kVA / 128 kW NT-200K200 kVA / 160 kW NT-260K260 kVA / 208 kW NT-320K320 kVA / 256 kW NT-400K400 kVA / 320 kW NT-500K500 kVA / 400 kW | 305-499 Vac (100% load) | 380/400/415 Vac, 3P4W+PE | 0 to 40ºC | NT-20~80K600 x 800 x 1400 mm NT-100K/120K800 x 830 x 1700 mm NT-160K/200K1200 x 830 x 1700 mm NT-260~400K1600 x 995 x 1950 mm NT-500K1900(3) x 995 x 1950 mm |