EL4900-series regenerative electronic loads

Power Without Compromise

The Keysight EL4900 series are compact, regenerative DC electronic loads for midrange applications. Available in 1U and 2U sizes, they return absorbed energy to the grid, cutting power use and cooling costs. Their space-efficient design lowers energy costs, saves floor space, and speeds integration—while delivering reliable performance and flexible features in one solution. Paired with PathWave advanced Power Suite, the EL4900 adds fast automation, deeper insights, and efficient validation of complex power devices—without compromise.

Up to 6 kW in 1U models available from 2 kW to 12 kW, parallelable up to 192 kW. Sink power efficiently with up to 95% returned to the grid.

EL4900-series regenerative electronic loads

Range features

A high level overview of what this range offers

  • Deliver a complete regenerative load for versatile testing needs.

  • Provide voltage options of 80 V, 500 V, and 800 V, with current sinking up to 240 A for broad application coverage.

  • Up to 6 kW in 1U models available from 2 kW to 12 kW, parallelable up to 192 kW. Sink power efficiently with up to 95% returned to the grid. Maximize rack efficiency with industry-leading compact 1U or 2U designs.

  • Save valuable rack space with stackable parallel connections, up to 16 units.

Downloads

for EL4900-series regenerative electronic loads

pdf
4 tips for Integrating and using ATE System Power Supply
Download
pdf
EL4900 Series Regenerative DC Electronic Loads
Download

What’s in this range?

All the variants in the range and a comparison of what they offer

ParameterEL4913AEL4915AEL4916AEL4923AEL4925AEL4926AEL4933AEL4935AEL4936AEL4943AEL4945AEL4946A

Power class

2 kW

2 kW

2 kW

4 kW

4 kW

4 kW

6 kW

6 kW

6 kW

12 kW

12 kW

12 kW

Voltage rating

80 V

500 V

800 V

80 V

500 V

800 V

80 V

500 V

800 V

80 V

500 V

800 V

Current rating

40 A

12 A

8 A

80 A

24 A

16 A

120 A

36 A

24 A

240 A

72 A

48 A

Power rating

2 kW

2 kW

2 kW

4 kW

4 kW

4 kW

6 kW

6 kW

6 kW

12 kW

12 kW

12 kW

Programming accuracy – Voltage

0.03% + 24 mV

0.03% + 150 mV

0.03% + 240 mV

0.03% + 24 mV

0.03% + 150 mV

0.03% + 240 mV

0.03% + 24 mV

0.03% + 150 mV

0.03% + 240 mV

0.03% + 24 mV

0.03% + 150 mV

0.03% + 240 mV

Programming accuracy – Current

0.1% + 40 mA

0.1% + 12 mA

0.1% + 8 mA

0.1% + 80 mA

0.1% + 24 mA

0.1% + 16 mA

0.1% + 120 mA

0.1% + 36 mA

0.1% + 24 mA

0.1% + 240 mA

0.1% + 72 mA

0.1% + 48 mA

Programming accuracy – Resistance

3 mΩ

10 mΩ

10 mΩ

3 mΩ

10 mΩ

10 mΩ

3 mΩ

10 mΩ

10 mΩ

3 mΩ

10 mΩ

10 mΩ

Programming accuracy – Power

0.5% + 10 W

0.5% + 10 W

0.5% + 10 W

0.5% + 20 W

0.5% + 20 W

0.5% + 20 W

0.5% + 30 W

0.5% + 30 W

0.5% + 30 W

0.5% + 60 W

0.5% + 60 W

0.5% + 60 W

Readback accuracy – Voltage

0.03% + 24 mV

0.03% + 150 mV

0.03% + 240 mV

0.03% + 24 mV

0.03% + 150 mV

0.03% + 240 mV

0.03% + 24 mV

0.03% + 150 mV

0.03% + 240 mV

0.03% + 24 mV

0.03% + 150 mV

0.03% + 240 mV

Readback accuracy – Current

0.1% + 60 mA

0.1% + 12 mA

0.1% + 8 mA

0.1% + 120 mA

0.1% + 24 mA

0.1% + 16 mA

0.1% + 200 mA

0.1% + 36 mA

0.1% + 24 mA

0.1% + 380 mA

0.1% + 72 mA

0.1% + 48 mA

Readback accuracy – Power

0.5% + 10 W

0.5% + 10 W

0.5% + 10 W

0.5% + 20 W

0.5% + 20 W

0.5% + 20 W

0.5% + 30 W

0.5% + 30 W

0.5% + 30 W

0.5% + 60 W

0.5% + 60 W

0.5% + 60 W

Load regulation – Voltage

≤ 16 mV

≤ 100 mV

≤ 160 mV

≤ 16 mV

≤ 100 mV

≤ 160 mV

≤ 16 mV

≤ 100 mV

≤ 160 mV

≤ 16 mV

≤ 100 mV

≤ 160 mV

Load regulation – Current

≤ 40 mA

≤ 12 mA

≤ 8 mA

≤ 80 mA

≤ 24 mA

≤ 16 mA

≤ 120 mA

≤ 36 mA

≤ 32 mA

≤ 240 mA

≤ 72 mA

≤ 64 mA

CV range

0 to 80 V

0 to 500 V

0 to 800 V

0 to 80 V

0 to 500 V

0 to 800 V

0 to 80 V

0 to 500 V

0 to 800 V

0 to 80 V

0 to 500 V

0 to 800 V

CV resolution

1 mV

10 mV

10 mV

1 mV

10 mV

10 mV

1 mV

10 mV

10 mV

1 mV

10 mV

10 mV

CV tempco

≤ 30 ppm/°C

≤ 30 ppm/°C

≤ 30 ppm/°C

≤ 30 ppm/°C

≤ 30 ppm/°C

≤ 30 ppm/°C

≤ 30 ppm/°C

≤ 30 ppm/°C

≤ 30 ppm/°C

≤ 30 ppm/°C

≤ 30 ppm/°C

≤ 30 ppm/°C

CC range

0 to 40 A

0 to 12 A

0 to 8 A

0 to 80 A

0 to 24 A

0 to 16 A

0 to 120 A

0 to 36 A

0 to 24 A

0 to 240 A

0 to 72 A

0 to 48 A

CC resolution

10 mA

1 mA

1 mA

10 mA

1 mA

1 mA

10 mA

1 mA

1 mA

10 mA

10 mA

10 mA

CC tempco

≤ 50 ppm/°C

≤ 50 ppm/°C

≤ 50 ppm/°C

≤ 50 ppm/°C

≤ 50 ppm/°C

≤ 50 ppm/°C

≤ 50 ppm/°C

≤ 50 ppm/°C

≤ 50 ppm/°C

≤ 50 ppm/°C

≤ 50 ppm/°C

≤ 50 ppm/°C

CR load resistance range

0.03 to 2,400 Ω

0.3 to 15,000 Ω

0.45 to 22,500 Ω

0.015 to 1,200 Ω

0.15 to 7,500 Ω

0.22 to 11,250 Ω

0.01 to 800 Ω

0.1 to 5,000 Ω

0.15 to 7,500 Ω

0.005 to 400 Ω

0.05 to 2,500 Ω

0.08 to 3,750 Ω

CR resolution

1 mΩ

10 mΩ

10 mΩ

1 mΩ

10 mΩ

10 mΩ

1 mΩ

10 mΩ

10 mΩ

1 mΩ

10 mΩ

10 mΩ

CP range

0 to 2 kW

0 to 2 kW

0 to 2 kW

0 to 4 kW

0 to 4 kW

0 to 4 kW

0 to 6 kW

0 to 6 kW

0 to 6 kW

0 to 12 kW

0 to 12 kW

0 to 12 kW

CP resolution

1 W

1 W

1 W

1 W

1 W

1 W

1 W

1 W

1 W

1 W

1 W

1 W

Maximum slew rate (rise/fall slope)

10 A/ms

3 kA/s

2 kA/s

20 A/ms

6 kA/s

4 kA/s

30 A/ms

9 kA/s

6 kA/s

60 A/ms

18 kA/s

12 kA/s

Line regulation – Voltage

≤ 16 mV

≤ 100 mV

≤ 160 mV

≤ 16 mV

≤ 100 mV

≤ 160 mV

≤ 16 mV

≤ 100 mV

≤ 160 mV

≤ 16 mV

≤ 100 mV

≤ 160 mV

Line regulation – Current

≤ 24 mA

≤ 7.2 mA

≤ 4.8 mA

≤ 48 mA

≤ 14.4 mA

≤ 9.6 mA

≤ 72 mA

≤ 28.8 mA

≤ 14.4 mA

≤ 144 mA

≤ 57.6 mA

≤ 28.8 mA

Protection – Overvoltage

82 V

530 V

835 V

82 V

530 V

835 V

82 V

530 V

835 V

82 V

530 V

835 V

Protection – Overcurrent

42 A

12.5 A

8.4 A

84 A

25 A

16.8 A

26 A

37 A

25.2 A

252 A

75 A

50.4 A

Protection – Overpower

2,040 W

2,040 W

2,040 W

4,080 W

4,080 W

4,080 W

6,120 W

6,120 W

6,120 W

12,240 W

12,240 W

12,240 W