iSeries – Digital Industrial Gas Sensors
- Technology
- Volatile organic compound (VOC) sensors
- Partner
- Honeywell
Easily integrate the iSeries into your instrument with pre-calibration and a digital interface, reducing downtime and cost of ownership. The iSeries multi gas detector sensors target carbon monoxide, hydrogen sulfide, oxygen, sulfur dioxide, and combustible gases & vapors, making them ideal for use in portable life safety devices, hand-held gas detectors, and other instruments.
![iSeries - Digital Industrial Gas Sensors](https://acalbfi.b-cdn.net/media/jpg/PI_Honeywell_iSeries_sps-siot-citytech-i-series-3-1200x1200.jpeg)
Simplify instrument design and speed up development with the iSeries, which is pre-calibrated and boasts a compact, low-profile design. These sensors are built to meet global performance standards and are RoHS compliant, with an extended operating life of five years and extended temperature and humidity range.
Benefit from a long lifespan, early warning for sensor malfunction, and multiple application possibilities with the Honeywell iSeries digital gas sensors. With interchangeable sensors featuring the same dimensions, communication protocol, and bias voltage, downtime is reduced and instrument performance is enhanced.
Downloads
for iSeries - Digital Industrial Gas Sensors
What’s in this range?
All the variants in the range and a comparison of what they offer
Sensor | Target Gas | Operating Principle | Range | Accuracy | Long-Term Output Drift | Expected Operating Life | Model |
---|---|---|---|---|---|---|---|
iCO | Carbon Monoxide (CO) | Electrochemical | 0 to 1000 ppm | ±5% of measuring value | <5% signal loss per annum | 5 years in air | AB010-R01D-CIT |
iSO2 | Sulfur Dioxide (SO2) | Electrochemical | 0 to 20 ppm | ±5% of measuring value | <10% signal loss per annum | 5 years in air | AD300-R04D-CIT |
iO2 | Oxygen (O2) | Lead-free electrochemical | 0% to 25% vol. O2- The sensor can read up to 30% O2 | ±3% vol. O2 | <5% signal life over operating life | 5 years in air | AAW85-07WD-CIT |
iH2S | Hydrogen Sulfide (H2S) | Electrochemical | 0 ppm to 200 ppm | ±5 % of measuring value | <10% signal life per annum | 5 years in air | AC400-R00D-CIT |
iLEL75 | Combustible gases and vapours | Catalytic Oxidation | 0 % to 100 % LEL | 5 % LEL | <3 % signal per month | 5 years in air | PM 979-600D-CIT |
iLEL75C | Combustible gases and vapours up to C6 | Catalytic Oxidation | 0 % to 100 % LEL | 5 % LEL | <3 % signal per month | 5 years in air | PM 989-600D-CIT |
iLEL75M | Methane and hydrogen | Catalytic Oxidation | 0 % to 100 % LEL | 5 % LEL | <3 % signal per month | 5 years in air | PM 999-600D-CIT |