iSeries – Digital Industrial Gas Sensors

Easily integrate the iSeries into your instrument with pre-calibration and a digital interface, reducing downtime and cost of ownership. The iSeries multi gas detector sensors target carbon monoxide, hydrogen sulfide, oxygen, sulfur dioxide, and combustible gases & vapors, making them ideal for use in portable life safety devices, hand-held gas detectors, and other instruments.

iSeries - Digital Industrial Gas Sensors

Simplify instrument design and speed up development with the iSeries, which is pre-calibrated and boasts a compact, low-profile design. These sensors are built to meet global performance standards and are RoHS compliant, with an extended operating life of five years and extended temperature and humidity range.

Benefit from a long lifespan, early warning for sensor malfunction, and multiple application possibilities with the Honeywell iSeries digital gas sensors. With interchangeable sensors featuring the same dimensions, communication protocol, and bias voltage, downtime is reduced and instrument performance is enhanced.

Downloads

for iSeries - Digital Industrial Gas Sensors

pdf
Overview Flyer – Honeywell iSeries
Download

Contact us

To request further information and availability please feel free to contact us right away.Or just fill out our contact form for a member of the sales team to respond to you.

Mandatory field: please enter your phone number.

In submitting this enquiry form you confirm you have read and agree to our privacy policy .

There was an error while sending the form. Please try again.

What’s in this range?

All the variants in the range and a comparison of what they offer

SensorTarget GasOperating PrincipleRangeAccuracyLong-Term Output DriftExpected Operating LifeModel

iCO

Carbon Monoxide (CO)

Electrochemical

0 to 1000 ppm

±5% of measuring value

<5% signal loss per annum

5 years in air

AB010-R01D-CIT

iSO2

Sulfur Dioxide (SO2)

Electrochemical

0 to 20 ppm

±5% of measuring value

<10% signal loss per annum

5 years in air

AD300-R04D-CIT

iO2

Oxygen (O2)

Lead-free electrochemical

0% to 25% vol. O2- The sensor can read up to 30% O2

±3% vol. O2

<5% signal life over operating life

5 years in air

AAW85-07WD-CIT

iH2S

Hydrogen Sulfide (H2S)

Electrochemical

0 ppm to 200 ppm

±5 % of measuring value

<10% signal life per annum

5 years in air

AC400-R00D-CIT

iLEL75

Combustible gases and vapours

Catalytic Oxidation

0 % to 100 % LEL

5 % LEL

<3 % signal per month

5 years in air

PM 979-600D-CIT

iLEL75C

Combustible gases and vapours up to C6

Catalytic Oxidation

0 % to 100 % LEL

5 % LEL

<3 % signal per month

5 years in air

PM 989-600D-CIT

iLEL75M

Methane and hydrogen

Catalytic Oxidation

0 % to 100 % LEL

5 % LEL

<3 % signal per month

5 years in air

PM 999-600D-CIT